4 PCI Express (PCIe)

The main technical inovation of PCI Express is a serial data transmission compared to the parallel interfaces of

other computer bus systems like ISA, PCI and PCI-X.

PCI Express denes a serial point-to-point connection, the so-called Link:

Selectable Width

D

ev

ic

A

D

ev

ic

B

Ref. Clock

Ref. Clock

The data transfer within a Link is done via Lanes, representing one wire pair for sending and one wire pair for

receiving data:

TX

Logic

D+

Component A

Component B

D+

V

BIAS

V

BIAS

D-

D-

RX

Logic

RX

Logic

TX

Logic

This design leads to a full duplex connection clocked with 2.5 GHz capable of transfering a data volume of 250

MB/s per lane in each direction. Higher bandwith is implemented by using multiple lanes silmutaneously. A PCI

Express x16 slot for example uses sixteen lanes providing a data volume of 4 GB/s. For comparison: when using

conventional PCI the maximum data transfer rate is 133 MB/s, PCI-X allows 1 GB/s but only in one direction

respectively. A PCIe expansion board (x1 like Meinberg GPS receivers for example) can always be used in slots

with a higher lane width (x4, x8, x16):

   Interoperability

 Slot

  x1

  x4

  x8

  x16

 Card

   x1

  Yes   Yes   Yes   Yes

   x4

  No

  Yes   Yes   Yes

   x8      No      No      Yes     Yes

  X16    No

  No    No    Yes

One of the strong points of PCI Express is the 100% software compatibility to the well known PCI bus, leading

to a fast spreading. The computer and the operating system are seeing the more powerfull PCIe bus just as the

convetional PCI bus without any software update.

PTP270PEX

Date: 22nd November 2012

11

Summary of Contents for PTP270PEX

Page 1: ...MANUAL PTP270PEX IEEE 1588 Computer Clock 22nd November 2012 Meinberg Radio Clocks GmbH Co KG...

Page 2: ......

Page 3: ...7 3 4 4 Two Step or One Step 8 3 4 5 End To End E2E or Peer To Peer P2P Delay Measurements 8 3 4 6 Mode Recommendations 8 3 4 7 Message Rate Settings 8 3 4 8 ANNOUNCE Messages 9 3 4 9 SYNC FOLLOWUP M...

Page 4: ...nberg Radio Clocks GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 30 Internet http www meinberg de Mail info meinberg de Date 2010 06 08 PTP270PEX Date...

Page 5: ...stalling the driver correctly 2 2 Mode of operation The on board Time Stamp Unit TSU integrated in a FPGA Field Programmable Gate Array programmable logic device monitors the data tra c on the MII int...

Page 6: ...r a continuous stream of events at a lower rate depending on the transmission speed of COM1 can be measured The format of the output string is described in the technical speci cations at the end of th...

Page 7: ...RJ45 with magnetics input signals time capture output signals signal generator PCI Express Bus register set single board computer SBC running PTP stack microcontroller reference oscillator O T CXO Tx...

Page 8: ...egrade the accuracy therefore classic layer 2 and 3 Ethernet switches with their store and forward technology are not suitable for PTP networks and should be avoided With activating the HQ Filter see...

Page 9: ...reached its nominal value the nanoseconds are reset again This procedure leads to a maximum deviation of 20 nsec of the pulse per second 1PPS of the PTP Master compared to the 1PPS of the GPS referen...

Page 10: ...hronization link 3 4 2 Network Layer 2 or Layer 3 PTP IEEE 1588 2008 o ers a number of so called mappings on di erent network communication layers For Meinberg products you can choose between running...

Page 11: ...s to be redirected and ows into the other direction A PTP slave in a sync infrastructure using E2E would in this case apply the wrong delay correction calculations until it performs the next delay mea...

Page 12: ...clock or the primary one during initialization the devices re quire to receive at least two consecutive ANNOUNCE messages Continuing our example it would take the 6 seconds to determine that the curre...

Page 13: ...the term jitter is used to describe the maximum deviation of the measured o sets around a certain mean value This time jitter of standard non PTP compliant switches can be in the range of 100 ns up to...

Page 14: ...direction Higher bandwith is implemented by using multiple lanes silmutaneously A PCI Express x16 slot for example uses sixteen lanes providing a data volume of 4 GB s For comparison when using conve...

Page 15: ...switch assigned are always available at the connector D SUB Pin Signal Signal level DIL switch 1 VCC out 5V 1 1 PPO0 out RS232 8 2 RxD in res RS232 3 TxD out res RS232 4 PPO1 out TTL 5 4 10MHz out TT...

Page 16: ...detected and the LED TX ashes whenever an outgoing PTP packet is detected by the Time Stamp Unit The 9 pin sub D connector is wired to the PTP270PEX s serial port COM0 Pin assignment can be seen in t...

Page 17: ...timecodes which are transmitted by modulating the pulse dura tion of a DC signal TTL in case of PTP270PEX see chapter IRIG standard format for details Transmission of the time code is synchronized to...

Page 18: ...7 3 IRIG Standard Format Page 15 7 3 IRIG Standard Format PTP270PEX Date 22nd November 2012 15...

Page 19: ...Page 16 7 Time codes 7 4 AFNOR Standard Format 16 Date 22nd November 2012 PTP270PEX...

Page 20: ...T Daylight Saving Time set during daylight saving time 64 Timezone O set Sign sign of TZ o set 0 1 65 TZ O set binary encoded 1 66 TZ O set binary encoded 2 O set from IRIG time to UTC time 67 TZ O se...

Page 21: ...L level ACCURACY OF PULSES depending on master oscillator TCXO OCXO LQ better than 100 nsec after synchronization and 20 minutes of operation OCXO MQ OCXO HQ better than 20 nsec after synchronization...

Page 22: ...emperature dependant dri free run 1 10 6 20 70 C 2 10 7 0 60 C Note 1 The accuracy in Hertz is based on the standard frequency of 10 MHz For example Accuracy of TCXO free run one day is 1 10 E 7 10 MH...

Page 23: ...t rungen von A1 2000 A2 2003 informationstechnischen Einrichtungen Limits and methods of measurement of radio interference characteristics of information technology equipment EN55024 1998 Grenzwerte u...

Reviews: