5 Attachment: Technical Information
5.4.12.1 Available BPE Modules
BPE Type
Connectors
Signal Outputs
BPE-1040
4x BNC female
Out 1 - Out 4: TC AM
BPE-2000
4x BNC female
Out 1: PPS, Out 2: 10 MHz
Out 3: TC DCLS, Out 4: TC AM
BPE-2010
4x BNC female
Out 1 - Out 4: PPS
BPE-2020
4x BNC female
Out 1 - Out 4: 10 MHz
BPE-2030
4x BNC female
Out 1 - Out 4: TC DCLS
BPE-2080
4x BNC female
Out 1 - Out 4: 2.048 MHz
BPE-2530
4x DFK / PhotoMos
PP 1 - PP 4: TC DCLS
1x BNC female
TC AM
BPE-3014
2x D-SUB9
TC DCLS / RS-422
BPE-3082
2x D-SUB9
4x 2048 kHz sine
BPE-5010
4x FO / ST
PPS
BPE-5020
4x FO / ST
10 MHz
BPE-5030
4x FO / ST
TC DCLS
BPE-8000 - Switchable Backplane Port Expander
BPE Module
Connectors
Signal Outputs
————————————————————————————————–
BPE-8000
4x BNC female
TTL
BPE-8100
4x ST
Fiber Optic - Multimode
BPE-8200
2x ST, 2x BNC female
2x Fiber Optic - Multimode, 2x TTL
BPE-8300
4x ST
Fiber Optic - Singlemode
BPE-8400
2x ST, 2x BNC female
2x Fiber Optic - Singlemode, 2x TTL
BPE-8500
4x ST
2x Fiber Optic - Multimode, 2x Fiber Optic - Singlemode
BPE-8600
4x BNC female
2048 kHz (ITU G.703-15 - 75
Ω
unbalanced) *
BPE-8700
4x BNC female
3x TTL, 1x Modulated Time Code - TC-AM **
*
Fixed outputs, no signal selection possible.
**
BNC sockets Out 1 - Out 3 are freely programmable, Out 4 is permanently set to TC AM.