The figure shows the network status and the module sensors (temperature, voltage ...).
Network Settings
To adjust the network parameters of the MDU-RSC,
you can open the "Device Configuration" window and
select "Network" from the drop-down list at the top.
By default, the DHCP service is enabled so that an IP
address is assigned automatically. If no DHCP server
could be found or no IP address has been assigned
via DHCP by any other reason, a fallback IP address
169.254.xxx.yyy will be set automatically (Zeroconf
1
).
If a static IP address shall be assigned, DHCP has
to be disabled in this area.
1
Zeroconf: If a computer configures a link local IP address, it selects an IP address between 169.254.1.0 and 169.254.254.255 by using a
random number generator.