12.8.23.1 SCG-U: Configuration via Web Interface
(Firmware version 6.19 or later)
If the SCG-U operates in an IMS system, the module can be easily configured via the web interface then.
Configuration Sample: SCG Output 3
In the "IO Configuration" menu each output frequency can be adjusted seperately. In the figure above the
following value is set:
Frequency Out 3 = Base Frequency * Scale
Frequency Out 3 = 44,1 kHz * 1/4
————————————————-
Frequency Out 3 =
11,025 kHz
Overview Configuration SCG-U Sound Clock Generator Outputs 1-4
Output Type:
Studio Clock Out
State:
Disabled
Enabled
Base Frequency:
32kHz
44.1kHz
48kHz
Scale:
1/8 to 256
100