Service Instructions Dishwashing Machine Model K-Tronic
Ident No.: 9627429
Page 25/30
FR1/2
310
Actual temperature in FR too high
(maximum exceeded)
Contactor sticking; temperature sensor
defective;
Plug contact temperature sensor with
high resistance
Temperature FR
too high
311
Temperature FR
too low
Required temperature permanently too
low
Heating element defective; Water
transfer;
Insufficient heating capacity
312
FR sensor shortcut
Short circuit FR temperature sensor
Short circuit in the wiring; Damp in the
connector.
313
FR sensor break
Cable to FR temperature sensor broken.
Connector incorrectly connected; Crimp
connection inadequate
314
FR sensor shortcut
Short circuit FR2 temperature sensor
Short circuit in the wiring; Damp in the
connector.
315
FR2 sensor break
Cable to FR2 temperature sensor
broken.
Connector incorrectly connected;
Crimp connection inadequate
316
FR: flow too low
Volume flow too low (no water)
Mains separation pump; Filling valve
317
FR2: flow too low
Volume flow too low (no water )
Mains separation pump; filling valve
318
Temperature FR2
too high
Actual temperature in FR2 too high
(maximum exceeded)
Contactor sticking; temperature sensor
defective;
Plug contact temperature sensor with
high resistance
319
Temperature FR12
too low
Required temperature permanently too
low
Heating element defective;
Water transfer;
Insufficient heating capacity
320
Malfunction p
ump PKSP
Signal "circulation pump error of PKSP "
pending
Motor overload switch triggered
321
Malfunction p
ump KSP1
Signal "circulation pump error of KSP1"
pending
Motor overload switch triggered
322
Malfunction p
ump KSP2
Signal "circulation pump error of KSP2"
pending
Motor overload switch triggered
Heat pump
510
Overload compressor
Motor overload switch compressor
511
Heat pump exhaust air
fan
Motor overload switch exhaust air fan
512
Heat pump tank water
circulation pump
Motor overload switch
Tank water circulation pump
513
Heat pump low
pressure
Low pressure switch has caused
disconnection
514
Heat pump
overpressure
Overpressure switch has caused
disconnection
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
valid from: 2005-09-01
Update: 2006-11-14 / S.5
W e reserve the right to change execution and construction!
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174