Service Instructions Dishwashing Machine Model K-Tronic
Ident No.: 9627429
Page 11/30
Information output
Note
Next maintenance in
Operating hours till next maintenance
Total Operation time
Counting up in the operating conditions
Filling/Heating/Ready for op./Operation
Running time
Wash pumps
Counting up while WP ON;
Applies as reference for maintenance!
Running time
Drying fan
Counting up while fan ON;
Number of baskets
If basket counter available;
FR water consumption
Display with one decimal place
FR water flow
Current actual value
FR2 water consump.
Display with 1 decimal place
(Only if available)
FR2 water flow
Current actual value
(Only if available)
Water consumption
filling valve
Only if water meter available (see separate
parameter)
Temperature PW
Actual temperature prewash tank (PW)
(Only if available)
Temperature WT6
Actual temperature wash tank 6 (WT6)
(Only if available)
Temperature WT5
Actual temperature wash tank 5 (WT5)
(Only if available)
Temperature WT4
Actual temperature wash tank 4 (WT4)
(Only if available)
Temperature WT3
Actual temperature wash tank 3 (WT3)
(Only if available)
Temperature WT2
Actual temperature wash tank 2 (WT2)
(Only if available)
Temperature WT1
Actual temperature wash tank 1 (WT1)
(Only if available)
Temperature PAR
Actual temperature pump final rinse (PAR)
(Only if available)
Temperature FR
Actual temperature final rinse 1 (FR)
Temperature FR2
Actual temperature final rinse 2 (FR2)
(Only if available)
Temperature Drying
Actual temperature drying
(Only if available)
Serial number
Option for calling up works parameters
Order number
Option for calling up works parameters
Heat pump
deactivated
or
Defrosting
in operation
or
Power regulation in
operation
Or
Defrosting
/ Power
regulation in operation
or
Hot gas by-pass OFF
Only if a heat pump is available
Output depending on the status of the entries
low
pressure switch
defrosting
or
high pressure switch
power regulation
6.3 I/O Status OUTPUT
When the machine is in the operating conditions
Machine Off, Fill/Heat, Ready for
Operation, Operating
and
Pumping out,
it is possible (option) to obtain information on
the status of digital inputs and outputs and the temperatures of an I/O module in the 1
st
,
3
rd
and 4
th
lines (the 2
nd
column continues to display the operating condition).
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
valid from: 2005-09-01
Update: 2006-11-14 / S.5
W e reserve the right to change execution and construction!
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
Summary of Contents for K-Tronic