4. Cover the module with an opaque cover.
5. Using a DC current probe, verify there is no current flowing in the DC wires between the
PV module and the Micro-inverter(make sure the current probe works correctly).
6. Disconnect the PV module DC wire connectors from the Micro-inverter.
7. Remove the Micro-inverter from the PV array racking.
Replace a Meikai Micro-inverter
Replace a Meikai micro-inverter follow the steps in the order shown
1. Disconnect the micro-inverter from the PV module follow the foresaid steps.
2. Install a new Meikai micro-inverter to the racking.
3. Connect the AC connectors of the new micro-inverter to the next micro-inverters; connect
the DC connectors to the PV module. Remove the opaque cover on the module and
complete the connection.
4. Close the AC circuit breaker to verify the operation status.
WARNING
:
Residual voltage exists in the inverter; the inverter cannot be maintained
within 5 minutes until the capacitor is fully discharged.