First connect the positive DC wire from the PV module to the negatively marked DC connector (female
socket) of the Micro-inverter. Then connect the negative DC wire from the PV module to the positively
marked DC connector (male socket) of the Micro-inverter. Repeat for all remaining PV modules using
one Micro-inverter for each module.
Step 6-Complete the Meikai Micro-inverter Installation Map
The Installation Map is a diagram of the physical location of each micro-inverter in your PV installation.
You can use the blank map in the Appendix to record micro-inverter placement for your system. When
your map is complete, send it to Meikai as described below. Meikai then uses this information to provide
you with detailed information about the performance of your PV system and to allow you to see a
graphic representation of your PV system on the web-based monitoring and analysis. Feel free to
provide your own layout if a larger or more intricate installation map is required.
Complete the Meikai Micro-inverter installation map.
A. Each Meikai micro-inverter has a removable serial number label located on the mounting plate.
Peel off the label and affix it to the respective location on the installation map, which is
available at the Appendix section of this manual or Meikai website
http://www.meikai-cn.com
/.
B. Send the installation map to Meikai after completion.
Commissioning
WARNING
: Connect the Meikai Micro-inverter to the electrical utility grid only after
receiving prior approval from the utility company.
WARNING
:
Be aware that only qualified personnel must connect the Meikai
Micro-inverter to the electrical utility grid.
WARNING
: Make sure that all AC and DC wiring is correct. Make sure that none of the
AC and DC wires are pinched or damaged. Make sure that all junction boxes are
properly closed. Make sure the circuit breaker for DC and AC are installed.
NOTE
:
The
starting
voltage
for
Meikai
micro
-
inverter
is
24
V
,
the
Meikai
micro
-
inverter
start
to
operate
only
after
the
DC
input
voltage
is
24
V
or
above
,
the
RED
LED
indicates
the
Meikai
micro
-
inverter
is
in
normal
operation
.
Commissioning a Meikai Micro-inverter system:
1. Connect each micro-inverter to the respective PV module (make sure the module is in normal
operation), the RED LED on.