In normal operation only a small amount of water is drained within a few seconds after the pump
unit has stopped. An increased volume may indicate a defective main valve or air in the pipes. If
water also escapes while the pump is running, this indicates, for example, a defect in the high-
pressure valve (e.g. due to wear).
4.6.2.
High pressure nozzles
The high-pressure nozzles ensure extremely fine at-
omization of the injected water at pressures above
50 bar. They consist of the nozzle body (1), the
spring valve (2), the bolt (3) and the nozzle head (4).
Cleaning:
Blocked nozzles or nozzles with poor spray pattern can be unscrewed and disassembled. If the
nozzle is calcified, it might be cleaned in a descaling bath / acetic acid bath / ultrasonic bath. Af-
terwards rinse thoroughly and blow out.
In case of frequent problems with the nozzles due to calcareous or ferrous water, water treat-
ment should take place.
If it is observed that brass nozzles are not sufficiently resistant (e.g. chemically), they should be
replaced with stainless steel nozzles.
Summary of Contents for D-Line + MBWeich 4
Page 46: ...Seite 46 7 Anschlusspl ne Wiring plans 7 1 Touch Controller MBWEICH3...
Page 47: ...Seite 47 7 2 Touch Controller MBWEICH4...
Page 48: ...Seite 48 7 3 Touch Controller LC 2...
Page 49: ...Seite 49 7 4 Touch Controller LCS 2...
Page 50: ...Seite 50 7 5 Touch Controller LCM...
Page 51: ...Seite 51 7 6 Touch Controller LCM vario...
Page 52: ...Seite 52 7 7 Erweiterungsboxen Extension boxes...
Page 53: ...Seite 53 7 8 Anschlussschema Vario System Connection scheme Vario system...
Page 54: ...Seite 54 7 9 Pumpe inkl MBWEICH3 Pump incl MBWEICH3...
Page 55: ...Seite 55 7 10 Pumpe Sonderspannung Pump special voltage...
Page 56: ...Seite 56 7 11 Pumpe Vario inkl LCM vario Pump Vario incl LCM vario...