Seite 18
3.3
Installation of additional modules
Important information!
The hoses must be installed in such a way that they cannot rub against other com-
ponents/sharp edges. The hoses must not be bent too much. Non-observance will
reduce the lifetime of the hose.
The pressure relief module for connection to the connection
pipe
(Art. 7113 - STANDARD)
is mounted between the hydrau-
lic hose of the pump unit and the connection pipe. For the con-
nections of the T-piece, the information in chapter 3.5.2
” must be observed. The mounting position of the
valve should be with the solenoid upwards. The hose at the
connector should be led into the drain. The cable of the valve
connector is connected to the Touch Controller according to the
specifications in the chapter 7
“Anschlusspläne/Wiring plans”.
The additional module 2-house without pressure relief
(Art. 7114)
is mounted near the pump unit on a wall or alterna-
tively in the pump unit on the rear wall of the angle plate. The
mounting position of the valves should be with the solenoids
pointing upwards. The connector between the valves is con-
nected to the hydraulic hose of the pump unit. The two hydraulic
hoses behind the valves are connected to the connecting pipes
to the two compartments. The cable of the double valve con-
nector is connected to the Touch Controller according to the
specifications in the chapter 7
(version
LC-2
or
LCS-2
required!).
The additional module 2-house with pressure relief
(Art. 7115)
is mounted near the pump unit on a wall or alternatively in the
pump unit on the rear wall of the angle plate. The mounting po-
sition of the valve block should be with the solenoids pointing
upwards. The right connection (P) is connected to the hydraulic
hose of the pump unit. The hose at the nozzle (R) is led into the
drain. The two hydraulic hoses behind the valve block (A1 and
A2) are connected to the connecting pipes to the two compart-
ments. The cables of the double valve connectors are connect-
ed to the Touch Controller according to the specifications in the
chapter 7
“Anschlusspläne/Wiring plans” (version
LC-2
or
LCS-2
required!). The two valves at the inlet of the valve block
control the two outputs. The two valves at the block outlet each
serve as pressure relief.
NOTE
All protective conductors of the modules must be connected to the protective conductor ter-
minal in the touch controller. The multicore cables must be connected according to the wire
colors in the chapter 7
“Anschlusspläne/Wiring plans”. For the double valve connectors of the
2-house modules, the position of the respective connectors must be taken into account
(compare the function of the valves in the wiring plans).
Summary of Contents for D-Line + MBWeich 4
Page 46: ...Seite 46 7 Anschlusspl ne Wiring plans 7 1 Touch Controller MBWEICH3...
Page 47: ...Seite 47 7 2 Touch Controller MBWEICH4...
Page 48: ...Seite 48 7 3 Touch Controller LC 2...
Page 49: ...Seite 49 7 4 Touch Controller LCS 2...
Page 50: ...Seite 50 7 5 Touch Controller LCM...
Page 51: ...Seite 51 7 6 Touch Controller LCM vario...
Page 52: ...Seite 52 7 7 Erweiterungsboxen Extension boxes...
Page 53: ...Seite 53 7 8 Anschlussschema Vario System Connection scheme Vario system...
Page 54: ...Seite 54 7 9 Pumpe inkl MBWEICH3 Pump incl MBWEICH3...
Page 55: ...Seite 55 7 10 Pumpe Sonderspannung Pump special voltage...
Page 56: ...Seite 56 7 11 Pumpe Vario inkl LCM vario Pump Vario incl LCM vario...