8 APPLICATION EXAMPLES
8.2 Example 2
3-phase circuit breaker with single
interrupter per phase and common
operating mechanism
Test quantities
Main contact timing measured by the Timing M/R module
Auxiliary contact timing (one a & one b contact) measured
by the Control module
Coil current & voltage measured by the Control module
Main contact motion & velocity
Transducer in use
Linear, resistive, 150 mm
Others
No resistor contacts, no grading capacitors
Necessary settings in Breaker View
Breaker View
Number of phases
3
Operating mechanism
Common
How to connect
Number of interrupters per phase
1
Resistor contacts
None
Number of a-contacts
1
Number of b-contacts
1
Breaker View \
Pulse & Delay Times
These settings are depending on the circuit breaker
type. If you are uncertain please refer to the breaker
manufacturers data.
Breaker View \
Measurement Preferences
Coil current
On
Control voltage
On
Static voltage
On
Breaker View \ Measurement Preferences \
Measurement Time & Sample Interval
The default settings should be sufficient in most of
the cases.
Breaker View \ Measurement Preferences \
Motion Measurement Preferences
Transducer type
Linear, Resistive
Absolute (calibrated transducer)
On
Breaker View \ Measurement Preferences \
Motion Measurement Preferences \
Speed
Calculation points
Whenever possible do settings according to manu-
facturers definition. However if that is not available
you can make your own choice and use it as your
own reference.
Summary of Contents for TM1800
Page 2: ......
Page 7: ...CG0757JE ZP CG01E TM1800 7...
Page 17: ...CG0757JE ZP CG01E TM1800 17 3 System overview...
Page 25: ...CG0757JE ZP CG01E TM1800 25 3 System overview Keyboard in position 3...
Page 71: ...CG0757JE ZP CG01E TM1800 71 7 Perform testing...
Page 97: ...CG0757JE ZP CG01E TM1800 97 12 Quick Guide...
Page 103: ......