background image

LCB2000/2 AND LCB2500/2

Premium Loop & Circuit Breaker Testers

ORDERING INFORMATION

Item (Qty)

Order Code

Premium Loop/Circuit Breaker Tester 

LCB2000/2

Premium Loop/Circuit Breaker Tester

LCB2500/2

With download, printing and storage

Included Accessories

User Guide 

Depends on V

Variant

3-Wire Test Lead Set, 2Prods, 3 clips 

6231-632

Mains Plug Test Lead 

Depends on

variant

Test and Carry Case 

6420-122

Download Manager Software on CD 

6111-442

(LCB 2500/2 only)

Optional Accessories

UK Mains Plug Test Lead

6231-633

Euro Mains Plug Test Lead

6231-635

2-Wire Test Lead Set With Prods and Clips

6231-631

(not for 0.01

non-trip loop tests)

2 Wire Test Lead 5m long

6231-637

(not for 0.01

non-trip loop tests)

Lead Set (Earth Bond) (5 Pin)

6231-634

Switched Probe SP2

6231-636

Fused Probe and Clip Set 

6180-405

Computer Serial Lead (LCB 2500 only)

25955-025

Printer Serial lead (LCB 2500 only)

25955-026

Item (Qty)

Order Code

Optional Software

PowerSuite for Windows 

See supplier

(Comprehensive Electrical Testing Software)

NICEone

6111-403

(Certification software for producing NICEIC certificates)

PowerSuite XPress Certification Software

6111-519

Publications

Testing Electrical Installations (Book)

6172-129

‘A Stitch in Time’ (Video)

AVTM21-P8

‘Getting Down To Earth’ (Book)

AVTB25-TA

A practical manual on earth resistance testing

SAFETY

The LCB2000/2500/2 comply
with the latest international
directives concerning safety
and electromagnetic
compatibility.

The instruments meet the
requirements for double
insulation to IEC61010-1
(1995), EN61010-1 (1995)
Safety Requirements for
electrical equipment for
measurement, control, and
laboratory use.  Category III**,
300 Volts phase to earth
(ground) and 440 Volts phase
to phase, without the need for
separately fused test leads. If
required, fused test leads are
available as an optional
accessory.

** Relates to the transient over-
voltages likely to be met in
fixed wiring installations.

Electromagnetic
Compatibility

The LCB 2000/2500/2 series
complies with IEC 61326-1

Environmental
Conditions

Operating range:

-5 to +40ºC

Operating humidity:

90% RH

at 40ºC max.

Storage temperature range:

-25 to +65ºC

Calibration Temperature:

+20ºC

Maximum altitude:

2000 m

Dust and water protection:

IP54

Physical Specifications

Dimensions

Height:

230 mm (9.1 inches)

Width:

114 mm (4.5 inches)

Depth:

62 mm (2.4 inches)

Weight 

920 g (2.0lbs)

(including batteries)

Cleaning   

Wipe with a clean cloth
damped with soapy water or
Isopropyl 

UK 

Archcliffe Road  Dover
CT17 9EN  England 
T  +44 (0) 1304 502101  
F  +44 (0) 1304 207342

UNITED STATES 

4271 Bronze Way 
Dallas  TX75237-1088  USA
T  800 723 2861 (USA only) 
T  +1 214 330 3203  
F  +1 214 337 3038

OTHER TECHNICAL SALES OFFICES

Valley Forge USA, Toronto CANADA,
Mumbai INDIA, Trappes FRANCE,
Sydney AUSTRALIA, Madrid SPAIN
and the Kingdom of BAHRAIN.

Registered to ISO 9001:2000 Reg no. Q 09290

Registered to ISO 14001  Reg no. EMS 61597

LCB2000_2_LCB2500_2_DS_en_V10

www.megger.com
Megger is a registered trademark

Summary of Contents for LCB2000/2

Page 1: ...of operation live display of R1 R2 values and efficiency provided by the downloading of data When combined with software certification the system provides a highly professional image for the contractor combined with the ever increasing requirement for traceability of test results The LCB2500 2 offers comprehensive data storage options with individual test results being quickly stored with relevant...

Page 2: ...plied with a pre wired plug for making connections via the standard socket outlets and a three wire leadset with probes and clips This enables connection to be made easily to a wide variety of systems Selectable RCD Types The LCB2000 2 and LCB2500 2 may be easily set to test General purpose Selective or dc sensitive RCDs Tests Programmable RCDs The Megger LCB2000 2 and LCB2500 2 cater for programm...

Page 3: ...e delayed Selective and d c Sensitive Nominal Supply 230 V 50 Hz Supply Range 100 280 V 45 65 Hz 1 2I n TEST CONTACT VOLTAGE Displayed range 0 V to 90 V Measurement range 5 V to 90 V LOOP RESISTANCE measured at 1 2 I n I n RESOLUTION 10 0 5 kΩ to 9 kΩ 30 170 Ω to 3 kΩ 100 50 Ω to 900 Ω 300 17 Ω to 300 Ω 500 10 Ω to 180 Ω 1000 5 Ω to 90 Ω 2 SECOND NO TRIP TEST at 1 2 I n optional Test current durat...

Page 4: ...t international directives concerning safety and electromagnetic compatibility The instruments meet the requirements for double insulation to IEC61010 1 1995 EN61010 1 1995 Safety Requirements for electrical equipment for measurement control and laboratory use Category III 300 Volts phase to earth ground and 440 Volts phase to phase without the need for separately fused test leads If required fuse...

Reviews: