MegaPoints Controllers
System2 Panel Controller User Reference
Revision 1
megapointscontrollers.co.uk
Page 17
First, it will cause the flashing LED indicator on that board to flash rapidly. This helps locate and
identify the board if you have multiple boards in one location.
Second, it will request that all CAN connected boards report in with their stats, assigned IP address,
CAN ID, Board Type and software version.
The blue IP address in the Status Log area is clickable and will take you to the management screen
for that board.
Any boards not connected to the Wi-Fi will show an IP address of “0.0.0.0”.
The above example shows three boards on the network in addition to the Servo-8 board we are
issuing the commands from. In summary we have:
The servo-8 board we are connected to via the web browser.
2 x Panel Controller, ID’s 493 and 340 with their respective IP addresses showing they are connected
to Wi-Fi.
1 x Relay Driver, ID 800 with an unassigned IP address (all zeroes) indicating this is not connected to
your Wi-Fi.
Clicking the Locate Board checkbox again will remove the tick and stop the boards rapid flashing.
This is reset upon reboot.