17
INSTALLATION INSTRUCTIONS
GAS HOOK-UP
Only the pressure regulator and hose assembly supplied with the grill should be used. Any replacement
pressure regulator and hose assembly must be specified by the grill manufacturer.
This grill is configured for LP gas. Do not use a Natural Gas supply.
Total gas consumption (per hour) with all burners set on
“
HI
”
:
Main burners 40,500 BTU/Hr.
Side burner
12,000 BTU/Hr.
Total
52,500 BTU/Hr.
LP GAS CYLINDER REQUIREMENTS
(9kg. Cylinder)
A dented or rusty LP gas cylinder may be hazardous and should be checked by your supplier. Never use
a cylinder with a damaged valve. The LP gas cylinder must be constructed and marked in accordance
with the specifications for LP gas cylinders for South Africa.
Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance. The Cylinder system must be arranged for vapor
withdrawal. The cylinder must include a collar to protect the Cylinder valve.
Remove the plastic valve cover from the LP gas cylinder. Make sure the grill gas hoses do not contact the
grease pan or grill firebox when the LP gas cylinder is placed into the cart.
CONNECTING THE LP GAS CYLINDER
To connect the LP Gas Supply Cylinder:
a) The cylinder valve should be in the
“
OFF
”
position. If not, turn the valve
clockwise until it stops.
b) Make sure the cylinder valve has the proper type internal thread for a
“
bullnose
”
regulator.
c) Make sure the burner valves are in the
“
OFF
”
position.
d) Inspect the valve connections, port and regulator assembly. Remove debris and inspect the hose
for damage.
e) When connecting the regulator assembly to the valve, use your hand to tighten the nut clockwise
until it stops. Use of a wrench could damage the quick coupling nut and result in a hazardous
situation.
f) Open the cylinder valve fully by turning the valve counterclockwise.
g) Before lighting the grill, use a soap and water solution to check all the connections for leaks.
h) If a leak is found, turn the cylinder valve
“
OFF
”
and do not use the grill until a local Liquid Propane
dealer can make repairs.
WARNING
Never attempt to use damaged or obstructed equipment. See your local LP gas dealer for repair.
Please make sure the cylinder valve connection device
shall properly and safely mate with the connection device
attached to the inlet of the pressure regulator.