b. Press the
button on the transmitter to set proper “Start Timer”. The chirp & LED pause will confirm
this enter. (Decrease “Start Timer” is necessary.)
c. Repeat the step1 – 4.
4. If the crank time is too short, (Engine not running, while stops cranks):
a. Press the
button twice on the transmitter to stop engine running.
b. Press
button on the transmitter to set proper “Start Timer”. The chirp & LED pause will confirm this
enter. (Increase “Start Timer ” is necessary.)
c. Repeat the step1 – 4.
TEST MODE
In this test mode, this system can test the Zone 2 (Instant ground trigger), the Zone 3 (Door trigger), and the
Zone 1 & Zone 4 (2 stage shock sensor) sensitivity. The installer can save time to test the 2 stage shock
sensor sensitivity and sensor without using the traditional arming/disarming procedures to test the sensors.
Enter:
1. Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in OFF position.
2. Push the Valet switch
10
times and hold it until
five
chirps with a long chirp is hearing then release the
valet switch. You are now in the Start feature
‘II’
programming mode.
a. Test the Zone 2 / Instant Ground Trigger & Zone 3 / Door Trigger:
Press and release the transmitter
and
button at the same time once. [1] LED flash, [1]
siren/horn chirp to indicate your are in Zone 2 / instant ground trigger and Zone 3 / Door trigger test
mode.
Trigger sensor
Siren chirps
Zone 2 / Instant Ground trigger (H5/4 Blue wire)
2
Zone 3 / Door trigger (H5/6 Green or H5/7 Violet wire)
3
b. Test the Zone 1 & Zone 4 / Two Stage Shock Sensor
(Connected to
H7
4 Pin Plug)
:
Press and release the transmitter
and
button at the same time again. [2] LED flash, [2]
siren/horn chirps to indicate your are in the shock sensor (connected to
H7
4 pin plug) test mode.
1. Activate the warn-away (first stage of the shock sensor / Zone 1), system will emit a short chirp.
2. Activate the full alarm (second stage of the shock sensor / Zone 4), system will emit a long chirp.
3. Continue to test the shock sensor until reach the proper sensitivity.
RETURN TO FACTORY DEFAULT SETTING:
1. Turn the ignition ON then OFF 3 TIMES and stay in OFF position.
2. Push the Valet switch
12
times and hold it until
six
chirp with a long chirp is hearing then release the valet
switch. You are now in the “Return To Factory Default Setting” programming mode.
ALARM FEATURE ALL RETURNS TO FACTORY DEFAULT SETTING:
and
3. Press and hold the
button at the same time on the transmitter for 6 seconds, there will be a
confirmation six chirp with 3 long chirp to confirm the system “Alarm Feature I & II & III Programming all
returns to factory default setting.
START FEATURE ALL RETURNS TO FACTORY DEFAULT SETTING:
and
4. Press the
first, within 3 seconds press and hold the
button at the same time on the
transmitter for 6 seconds, there will be a confirmation six chirp with 3 long chirp to confirm the system
“Start Feature I & II Programming all returns to factory default setting.
Exit
:
Turn Ignition to 'ON' position, or leave it for 15 seconds. A 3 long chirps & 3 parking light flashes to
confirm exit.
SHUTDOWN DIAGNOSTICS
The unit has the ability to report the cause of the last shutdown of the remote start system.
Enter:
1.
Turn the Ignition switch to ‘ON position.
2.
Press the
button on the transmitter.
3.
The LED will now report the last system shutdown by flashing for one minute in the following grouped
patterns:
LED
Flashes
Shutdown Mode
22
Summary of Contents for MEGA 3600
Page 4: ...INSTALLATION DIAGRAM 4...