Programming

 

4.1 Programmed Schedule

1) 
2)  Each  schedule  setting  has  4  parameters  “Running  Speed”,  “Time  On”,  “Time  Off”,  Enable  / 

Disable.

3)

 

Programmed Schedule Priority: Schedule 1 > Schedule 2 .

4) Programmed Schedule Logic: If more than 1 schedule is enabled within the same time period, 

the controller will operate only with the highest priority schedule and speed, the corresponding 
indication light will on.

5)  Programmed  Schedule  Termination:  If  all  schedules  are  completed  with  its  setting  time,  the 

controller will switch back to the condition before the schedule.

6)  Programmed  Schedule  Manually  Disable:  When  any  programmed  schedule  is  running,  press 

any  button  (“UP”.  “DOWN”,  “Start/Stop”,  “Speed  1”,  “Speed  2”,  “Speed  3”)  in  the  monitoring 
interface  with  disable  all  programmed  schedules.  (Press  “Start/Stop”  will  stop  the  pump,  the 
last  running  speed  will  be  recorded,  the  operation  light  will  remain;  Press  “UP”,  or  “DOWN”, 
running  speed  add/reduce  10rpm  from  the  current  speed,  the  operation  light  will  off;  Press 
“Speed  X”,  the  selected  speed  will  replace  the  current  speed,  with  the  corresponding  speed 
indication light on)

7) The scheduled settings and auto recovery will not contradict each other. When there is error, 

the  variable  speed  driver  will  restore  to  the  settings  before  the  error.  (The  priority  setting  is  still 
applicable)

2 schedule settings available, preset speed at 1500RPM, 2400RPM.

4.2 Self Priming 

1)  Self  Priming  setting  has  3  parameters  “Self  Priming  Time”,  “Self  Priming  Speed”, 

“Enable/Disable”.

2) Self Priming function will be activated if the function is enable, the running speed is lower than 

the “Self Priming Speed” and the running time is less than the “Self Priming Time”.

3) Self Priming default as “Enable”.

4.3 Auto Recovery 

1
2)  When  there  is  Over  Current,  Over  Voltage  or  Low  Voltage  error,  the  variable  speed  driver  will 

recover automatically and will restart after 10 seconds.

3) In the first 5 seconds, the display will shows the “error details /error times” (e.g. “OC1 1T”). In the 

next 5 seconds, the display will shows the “Count down details / Count down time” (e.g. “AR 5” 
or “AS 5”)

4)  If  two  errors  happenedin  less  than  60  seconds  interval,  the  auto  recovery  time  will  increase 

once. If the auto recovery increase to 3 times, the system will direct to the Error menu, and will 
not auto recover.

5)  Press  “Start/Stop”  button  to  cancel  the  count  down  during  the  auto  recovery  process,  to 

activate the auto recovery immediately.

) Auto Recovery is a core function, with no setting options.

8

4.4 Power Failure Recovery

1) 

capacitance, the memory will be kept for 72 hours.

2) When the power is reconnected, the variable speed driver will restore to the settings before the 

error.

The current settings (Enable/disable, current speed, scheduled settings) are protected by the 

4.5 Real Time Clock 

1) Real time clock display time in “hours:minutes”
2) Long press “MODE” button at the “Time Display Page” to enter “Time Setting”.

4.6 Reset 

At the setting interface, switch to the Reset menu, display “RESET”, short press “Mode”, the 

Summary of Contents for 88029807

Page 1: ...SPV Pump Installation Operating Instructions MEPU18070642...

Page 2: ...nstallation 4 User s Guide 4 5 Menu Structure 6 7 Programming 8 Fault Treatment 9 Routine Maintenance 13 Service Repair Parts 13 Trouble Shooting 14 Replacement Parts 15 Dimension 16 Product Informati...

Page 3: ...of the following the maximum total head in metres Hmax 20m 6 the pump is to be supplied through a residual current device RCD having a rated residual operating current not exceeding 30 mA This applian...

Page 4: ...oceeding RELEASE ALL PRESSURE from pump and piping system NEVER tighten or loosen screws while pump is operation Do not block pump suction 1 2 Priming Pump In a flooded suction system water source hig...

Page 5: ...reset Speed 1 Quick Setting Preset Speed 2 Quick Setting Preset Speed 3 Quick Setting 2 2 2 Indication Light Reference S1 S2 S3 Running Light Operation Light Flashing Preset Speed 1 Enable 1 0 0 X 0 P...

Page 6: ...Short press Speed 3 Cancell E g SP 1000 Unit RPM E g P 0 Unit Watt W E g CI 0 00 E g 1S 1500 800 3400RPM E g 1O 00 00 00 00 23 59 E g 1F 0 00 00 00 23 59 E g 1E Off On Off E g PL 2 1 20 mins E g PS 2...

Page 7: ...When in the Time Dislay page Enter Time Setting When in other pages Enter Setting Interface Enter Monitoring Interface N A N A Short press Start Stop Start Stop Start Stop N A Auto Recovery Long press...

Page 8: ...Self Priming setting has 3 parameters Self Priming Time Self Priming Speed Enable Disable 2 Self Priming function will be activated if the function is enable the running speed is lower than the Self...

Page 9: ...e Over power of the power supply Power supply voltage exceeds controller setting UV The main electric current is too low Voltage Under Power supply disconnected driver discharging Supply voltage fluct...

Page 10: ...oring Interface Diagram 6 4 Power consumption display page Diagram 6 5 Time display page Short press Speed1 to Speed3 to switch to the 3 preset speeds the corresponding indication light will on as dia...

Page 11: ...Speed Schedule 2 Time On Schedule 2 Time Off Schedule 2 Enable Disable Schedule 3 Speed Self Priming Time Self Priming Speed Self Priming Enable Disable Auto Recovery pages As diagram 6 12 6 23 Diagra...

Page 12: ...y automatically If two errors happened in less than 60 seconds interval the auto recovery time will increase once If the auto recovery increase to 3 times the system will direct to the Error menu and...

Page 13: ...discharge and release all pressure from system before proceeding 2 Unscrew trap lid turn counterclockwise 3 Remove strainer basket and clean Be sure all holes in basket are clear flush basket with wat...

Page 14: ...W PUMP CAPACITY 1 Valve in suction or discharge line partly closed 2 Suction or discharge line partly plugged 3 Suction or discharge line too small 4 Plugged basket in skimmer or hair and lint straine...

Page 15: ...al Seal 1 13 02010246 O Ring for Flange 1 14 01021145 Flange 1 15 89020720 M8 35 Screw with Washer for Motor 4 16 03011075 M8 30 Screw 4 17 04020140 SPV150 Motor 1 18 01112082 Base 1 18 02010211 Arch...

Page 16: ...81 300 8 46 215 7 68 195 22 37 568 20 9 33 237 10 60 269 6 06 154 8 62 219 5 00 126 90 5 25 133 43 4 41 112 12 Product Information Code Mode Code Connection lnput Power Horsepower RPM 88029807 SPV150...

Reviews: