28
ENGLISH
Control panel
Use
TIG
1.
Set the power switch to the ON position.
Voltage status lamp goes on.
2.
Open the gas cylinder valve and set the
required flow.
3.
The machine fan starts. Press the
activation button on the welding handle.
The solenoid valve opens, gas flows out
and the ignition arc (HF) lights up (arc is
audible).
4.
Set the requisite welding current for the
thickness of the workpiece.
5.
Hold the tungsten electrode 2–4 mm from
the workpiece and press the arc ignition
button. When the welding arc ignites the
HF arc goes off and you can start welding.
MMA
1.
Set the power switch on the control panel to the ON position. The fan starts.
2.
Set the function selector on the control panel to ARC.
3.
Set the requisite current for the thickness of the workpiece.
IMPORTANT:
Connect all cables securely. If cables come loose while welding is in progress there is a risk of personal
injury and/or material damage.
Setting for stainless steel plate, TIG
(guidance only)
Plate
thickness
(mm)
Diameter, tungsten
electrode (mm)
Diameter,
wire (mm)
Current
type
Welding
current (A)
Gas flow
(l/min)
Welding speed
(cm/min)
1,0
2
1,6
DC plus
7–28
3–4
12–47
1,2
2
1,6
15
3–4
25
1,5
2
1,6
5–19
3–4
8–32
Settings for titanium and titanimum alloys, TIG
(guidance only)
Plate
thickness
(mm)
Type of
joint
Number
of beads
∅
tungsten
electrode
(mm)
∅
wire (mm)
Welding
current
(A)
Gas flow (l/min)
∅
gas
cover
(mm)
0.5
I
1
1.5
1.0
30–50
8–10
6–8
14–16
10
1.0
1
2.0
1.0–2.0
40–60
8–10
6–8
14–16
10
1.5
1
2.0
1.0–2.0
60–80
10–12 8–10 14–16
10–12
2.0
1
2.0–3.0
1.0–2.0
80–110 12–14 10–12 16–20
12–14
2.5
1
2.0–3.0
2.0
110–120 12–14 10–12 16–20
12–14
3.0
Y
1–2
3.0
2.0–3.0
120–140 12–14 10–12 16–20
14–18
4.0
2
3.0–4.0
2.0–3.0
130–150 14–16 12–14 20–25
18–20
5.0
2–3
4.0
3.0
130–150 14–16 12–14 20–25
18–20
6.0
2–3
4.0
3.0–4.0
140–180 14–16 12–14 25–28
18–20
7.0
2–3
4.0
3.0–4.0
140–180 14–16 12–14 25–28
20–22
8.0
3–4
4.0
3.0–4.0
140–180 14–16 12–14 25–28
20–22
Power switch
Fault status lamp
Selector
MMA/TIG
Minus connection
Gas connection
Quick connection
Plus connection
to workpiece
Current setting