15
IMPORTANT:
Only use spare parts and accessories recommended by the manufacturer.
Never immerse the spray gun in solvent or other fluid.
Be careful never to damage the holes in air cap, paint nozzle or paint nozzle.
TROUBLESHOOTING
Spray patterns
Problem
Action
Uneven
Air leaks in between the paint
nozzle and the connection.
Air leaks in between the air
setting ring and body or the
connection.
Air leaks in by the needle lock nut.
Air leaks in between the paint
hose and the container.
Dismantle and clean the parts and
refit. Replace the parts if they are
damaged.
Dismantle and clean the parts and
refit. Replace the parts if they are
damaged.
Tighten the needle lock nut.
Dismantle and clean the parts and
refit.
Half moon format
Clogged hole in the air cap.
Clean the nozzle with a nylon brush
(not a metal brush).
Thicker at one end
Blockage between the paint
nozzle and air cap.
Blockage at the paint nozzle’s
outlet.
Clean the holes.
Replace the air cap if the holes are
damaged.
Remove the paint nozzle and clean
the connection.
Thinner in the
middle
Too low viscosity.
Excessive paint flow.
Add undiluted paint too increase the
viscosity.
Turn the spray valve for less paint
flow (gives smaller spray pattern).
Thicker in the middle
Too high paint viscosity.
Excessive paint flow.
Add solvent to reduce the viscosity.
Turn the spray valve for more paint
flow.
Jula reserves the right to make changes. In the event of problems, please contact our service department
www.jula.com
Summary of Contents for 082-209