TROUBLESHOOTING
Symptom
Possible cause
Proposed action
Impaired capacity. Frequent
starting Low pressure value.
Intensive use or potential
leakage from couplings and/or
hoses. Clogged intake filter.
Replace the seals on the
couplings. Clean or replace
the filter.
The compressor stops and
automatically restarts after a
few minutes.
Tripping of the overheating
protection due to the motor
overheating.
Clean the ventilation holes in
the manifold. Ventilate the
room.
The compressor stops after a
few attempts.
Tripping of the overheating
protection due to the motor
overheating (disconnection
of connector, weak supply
voltage).
Switch on the pressure switch
button. Ventilate the room.
Wait a few minutes and the
compressor will automatically
restart.
The compressor does not stop
and the safety valve actuates.
Compressor malfunction or
faulty pressure switch.
Pull out the plug and contact
your service centre.
All other types of action must be performed by an accredited service centre and with the use of original
spare parts. Any modifications to the machine can put safety at risk and invalidate the warranty.