EN
15
USE
Unpack the ash vacuum and all accessories.
1. Release the snap-lock on each side of the
container and lift off the top part of the
ash vacuum.
2. Fit the filter unit underneath the top part.
3. Replace the top part on the container and
lock with the catches.
4. Insert the hose into the connector.
FIG. 2
Starting/switching off
Press the power switch to start and switch off
the ash vacuum.
FIG. 3
NOTE:
The ash vacuum must only be started when
the filter is fitted.
WARNING!
The ash vacuum must not be used to vacuum
toxic dust, liquid or hot or flammable
particles.
MAINTENANCE
NOTE:
Make sure the ash vacuum is not connected
to the mains when cleaning it.
1. Release the hose from the ash vacuum.
2. Remove the top part from the container.
FIG. 4
3. Empty and wash the dust container.
4. Wipe the dust container dry with a cloth.
5. Take out the filter and carefully clean. Do
not rinse with water.
FIG. 5
Symbols
Safety class II, extra or
double insulation.
Approved as per
applicable directives.
Recycle discarded product
in accordance with local
regulations.
DESCRIPTION
1. Hose
2. Power switch
3. Handle
4. Snap-lock
5. Power cord
6. Ash container
7. Connection
8. Tube
FIG. 1
TECHNICAL DATA
Rated voltage
230 V ~ 50 Hz
Engine capacity
900 W
Suction power
180 W
Safety class
II
Noise level
78 dB
Volume
18 l
Hose length
1.5 m
Cord length
7.5 m
Range
8.5 m
Max temperature of ash
60 °C
Dimensions
Ø 28 x 41 cm
Summary of Contents for 002-795