background image

INSTRUCTIONS PW530

6

Figure 18

Figure 22

Figure 20

Figure 21

Figure 19

3.2 Installation of the motor

1. Choose the correct dimensions of the motors and position to be installed.
2. Check if the brackets mounting surface is smooth, vertical and rigid.
3. Arrange the cable conduit for power supply cable of the motors.
4. In order to obtain the optimal supporting from the rear plate, please assemble two post brackets and one rear metal
    plate according to Figure 18.
5. Remove the back cover of the motor as shown in Figure 19
6. Place the door leaves at the closed position.

Figure 23

11. Clamp and fix the motor front plate on the door temporarily.

7. Refer to the distance of “B” in Figure 21, place the rear plate in the correct position on the mounting surface.
8. Place two post brackets on the surface to be installed and mark the drilling points, then drill minimum diameter
    of 8mm holes by four on the mounting surface to be installed and fasten up the brackets with screws and washers.
9. Please make sure the front plate is completely installed horizontally.

139

Summary of Contents for PW530

Page 1: ...SWING GATE OPENERS FOR RESIDENTIAL with limit switch LED indicator USER MANUAL 24V DC GEAR MOTOR PW530 Flashing Light Control box Push Button Gate 2 Gate 1...

Page 2: ......

Page 3: ...2 2 Tools need for Installation 2 3 Installation 2 4 Cable Connection 2 5 Power Connection 3 Installation 3 1 Preparation for Motor Installation 3 2 Installation of the motor 3 3 Limit switch adjustme...

Page 4: ...operly before installing the gate automated system and confirm the gates are appropriate for the application Do not let children operate or play with the gate automated system Do not cross the path of...

Page 5: ...requires very low voltage and non professionally trained personnel is required in installation however the users are advised to read this installation manual carefully before installation After decide...

Page 6: ...and force regulations 3 Make sure there is no serious friction existing in the opening or closing travel of the gate leaves 4 Make sure the gate is at horizontal level that the gate will not move asid...

Page 7: ...calculated from the value of A and the leaves opening angle Ex If A 160mm with the leaves opening angle of 100 degrees then the value of B is approximate 190mm Please make sure B and A are similar or...

Page 8: ...tal plate according to Figure 18 5 Remove the back cover of the motor as shown in Figure 19 6 Place the door leaves at the closed position Figure 23 11 Clamp and fix the motor front plate on the door...

Page 9: ...Loosen the screws and slide the cover out 2 Loosen the screws on the Limit Switches and adjust to the proper position 3 Tight up the screws and put the cover back 3 3 Limit switch adjustment 12 Lift...

Page 10: ...4 2A for maximum 10 seconds 450 kg per leaf 3 5 meters 20 20 50 846mm 129mm 127mm 24Vdc motor with mechanical release Worm gear 5500N 24Vdc 6A for maximum 10 seconds 550 kg per leaf 4 meters 20 20 50...

Page 11: ...INSTRUCTIONS PW530 9...

Page 12: ...INSTRUCTIONS PW530 10 34100 199 01 B...

Reviews: