background image

7.  SPECIFICATIONS 

 

Power 

AC 120V, 60Hz 

Current 1.5A 
Medication Capacity 

5ml 

Particle Size 

0.5 to 10 

μ

 m 

MMAD 4 

μ

 m 

Sound Level 

Around 60 dBA 

Maximum Medication capacity 13ml (cc) 

Average Nebulization Rate 

0.2ml/min 

Compressor Pressure Range 

30 to 36 Psi (210 to 250 KPa / 2.1 to 2.5 bar) 

Operating Pressure Range 

8 to 16 Psi (50 to 100Kpa / 0.5 to 1.0 bar) 

Liter Flow Range 

6 ~ 8 lpm 

Operating Temperature Range 10

˚

C to 40

˚

C (50

˚

F to 104

˚

F) 

Operating Humidity Range 

10 to 95% RH 

Storage Temperature Range 

-20

˚

C to 70

˚

C (-4

˚

F to 158

˚

F)  

Storage Humidity Range 

10 to 95 % RH 

Dimension (L x W x H) 

319x141x170mm (12.56” x 5.55” x 6.69”) 

Weight 

4.96Lbs (2.25kg

s

Standard Accessories 

Mouth Piece, Nebulizer, Air Tube, Filters 
(5pcs), Child Mask. 

 

 
Protection against electric shock 

- Class II Equipment 

 

- Type BF applied parts:   
- Mask, baby pacifier 

 
Protection against harmful ingress of water 
- IPX0 (Ordinary) 
 
Degree of safety in the presence of flammable anesthetics or oxygen 
- No AP/APG (Not suitable for use in the presence of flammable anesthetics or 
oxygen) 
 
Mode of operation – continuous. 
 
 
 
 
 
 
 
 

Summary of Contents for Airial MQ0911

Page 1: ...NST Compressor Nebulizer Guidebook MODEL MQ0911 READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE...

Page 2: ...passages for the treatment of asthma allergies COPD and other respiratory ailments With proper care and use it will provide you with many years of reliable treatment The Airial TM is intended for use...

Page 3: ...cord or the unit in liquid Do not use while bathing Do not reach for a unit that has fallen into water immediately unplug the unit 2 Never operate the unit if it has any damaged parts including power...

Page 4: ...may damage the unit 2 Disconnect the unit from the electrical outlet before cleaning 3 Clean all necessary parts after each use as instructed in this guidebook Save These Instructions 4 OPERATING YOU...

Page 5: ...outlet 5 CLEANING It is recommended that the nebulizer and the mask or other patient accessory interface used are thoroughly cleaned with hot water after each use and cleaned with a mild detergent aft...

Page 6: ...Then wash them in hot tap water 4 Submerge these parts in the vinegar and water solution for thirty minutes 5 Complete Rinsing Steps 3 5 Cleaning the Compressor 1 Wipe daily with a damp cloth 2 Do no...

Page 7: ...04 F Operating Humidity Range 10 to 95 RH Storage Temperature Range 20 C to 70 C 4 F to 158 F Storage Humidity Range 10 to 95 RH Dimension L x W x H 319x141x170mm 12 56 x 5 55 x 6 69 Weight 4 96Lbs 2...

Page 8: ...ects in material and workmanship for lifetime This warranty is valid for the original purchaser only Any alterations abuse misuse or accidental damage voids this warranty Please call Medquip Inc at 88...

Reviews: