SERVICE  WARRANTY.  Meditech  Ltd.  undertakes  half  year  warranty  on  the 
servicing carried out. 
 
SOFTWARE  WARRANTY.  The  CardioVisions  software  under  normal  use  will 
perform  substantially  in  accordance  with  the  accompanying  written/electronic 
documents for a period of ninety (90) days from the date of receipt. 
 
This  warranty  is  valid  at  the  representative  address  of  Meditech  Ltd.  unless 
otherwise  displayed  upon  a  commercial  invoice  or  any  other  valid  business 
document duly signed by the supplier and the recipient of the Meditech product. If 
such  business  document  displaying  a  certain  site  for  warranty  validity  cannot  be 
presented, this warranty is valid at Meditech HQ office in Budapest, Hungary. This 
warranty does not cover any malfunction or defects of the recorder unit or any of its 
accessories arising from improper use, the use of inadequate accessories, accident, 
theft, or use of the recorder unit outside its operating environmental specifications 
and  intended  measurement  range.  Warranty  conditions  do  not  apply  to  putative 
defects  that  are  considered  to  be  defects  by  the  Partner  due  to  inadequate 
knowledge or improper use of the products. Products returned with such putative 
defects are subject to service checkup charge. Removing the closing label from the 
back  side  of  the  recorder  unit,  or  opening  the  unit  any  other  way  voids  this 
warranty. 

Exclusion  of  biohazard.  Meditech  will  not  accept  for  repair  potentially  infectious 
products  or  accessories,  especially  pouches  and  cuffs  that  might  have  been  in 
direct contact with the patient, and could not be, or (potentially) were not, properly 
disinfected, even within the warranty period. If a problem occurs within the warranty 
period, such accessories will be replaced without any physical inspection, reserving 
the rights to hold an inspection when found necessary. 

No  other  warranties.  Meditech  disclaims  all  other  warranties,  either  expressed  or 
implied,  including,  but  not  limited  to,  implied  warranties  of  merchantability  and 
fitness  for  a  particular  purpose,  with  regard to  the  recorder  unit,  any  accessory  or 
other accompanying hardware, and the software. 
No liability for consequential damages. In no event shall Meditech be liable for any 
special,  incidental,  indirect,  or  consequential  damages  whatsoever  (including, 
without limitation, damages for loss of business profits, business interruption, loss 
of business information, loss of data, or any other pecuniary loss) arising out of the 
use of or inability to use the recorder unit, its accessories and/or the CardioVisions 
software, even if Meditech has been advised of the possibility of such damages. 

 

Conventions 

ABPM-05/BlueBP-05 

ambulatory 

blood 

pressure 

monitors 

and 

CardioVisions/EasyABPM software are manufactured and developed by Meditech 
Ltd.  All  title  and  copyrights  in  and  to  the  CardioVisions/EasyABPM  software,  the 
accompanying  electronic  and  printed  materials  and  any  copies  of  the 
CardioVisions/EasyABPM 

software 

are 

owned 

by 

Meditech 

Ltd. 

CardioVisions/EasyABPM  software  is  protected  by  copyright  laws  and 

Summary of Contents for ABPM-05

Page 1: ...User Guide ABPM 05 BlueBP 05 Ambulatory Blood Pressure Monitors...

Page 2: ...11 7 Customize review print data 12 ABPM 05 manual programming 12 Patient information 13 Cuffs 14 Dimensions 14 Application 15 Batteries 16 Safety concerns 17 Cleaning protection 18 Maintenance 19 Dis...

Page 3: ...surge for reliable hypertension management and control Both ambulatory blood pressure monitors incorporate an algorithm validated to BHS British Hypertension Society and AAMI Association for the Advan...

Page 4: ...tion during measurement current pressure is displayed mmHg The device is switched off Systolic value of just completed measurement mmHg The blood pressure measurement is cancelled by pressing a button...

Page 5: ...Heart symbol blinking measurement in progress kPa Diastolic value of a just completed measurement kPa Buttons The monitor has 3 buttons start event and day night Any blood pressure measurement can be...

Page 6: ...event marker in a diary Day night button functions Marking the time of sleeping and awakening If the day night shift function is disabled during programming the patient can press the day night button...

Page 7: ...k and basic solutions 2 Setup the monitor 2 1 Install 2 AA batteries into the monitor Accumulator voltage should be over 2 5V To check press the Start button for at least 5 seconds 2 2 Setup communica...

Page 8: ...unit converts optical signals to electric ones and vice versa The twin optical cable transfers optical signals between the interface unit and the recorder The cable is flexible but it is sensitive to...

Page 9: ...PM 05 select the type of your interface unit select the required port or simply click on Test EasyABPM Device Read data BlueBP 05 If you want to use a BlueBP 05 with Bluetooth under Windows XP SP 2 fo...

Page 10: ...corder in case of BlueBP 05 is BB5_xxxx where xxxx is the last four digits of the serial number found on the back of the recorder After selecting the appropriate recorder the OK button becomes active...

Page 11: ...atient a sample is available on the installation CD and inform the patient about the goal and the expected results of the monitoring and about the use of the monitor 6 Retrieve data 6 1 Remove the uni...

Page 12: ...ght time Other settings are the same in all the three plans undecided cuff size 300 mmHg pressure limit LCD display enabled manual day night shift disabled Daytime starts at 6 00 while nighttime start...

Page 13: ...minute day night intervals 1 measurement plan 15 30 minute day night intervals Programming is in progress blinking signal Patient Information Wearing a thin shirt under the cuff is recommended It does...

Page 14: ...Event button the patient can mark events e g taking medication etc The time of going to and rising from bed can be marked by the Day night button Should the batteries run down during a monitoring ses...

Page 15: ...he cuff is placed above the brachial artery if possible Contrary to the usual placement with the tube pointing downwards the advantage is that the patient can wear a loose jacket over the cuff When pr...

Page 16: ...ult in measurement error and or in certain cases it causes damage to the main recorder unit Batteries Meditech ABPM 05 and BlueBP 05 operate either with two 1 5V AA normal batteries or with two 1 2V A...

Page 17: ...sion they can be replaced Monitoring will continue and data will not be lost Remove the batteries if the recorder is out of use If you do not use the recorder it is advisable to remove batteries since...

Page 18: ...ors are not specially protected against spills or ingression of water or other liquids Cleaning the monitor A recommended means of cleaning is to wipe the recorder with a disinfectant cleaning tissue...

Page 19: ...itech Ltd see relevant topic This warranty does not cover any malfunction or defects arising from improper use the use of inadequate accessories accident theft or use of the device outside operating e...

Page 20: ...ldren without supervision or children younger than 8 years Though the blood pressure measurement algorithm used in the monitors has been found to function properly on patients with atrial fibrillation...

Page 21: ...rement method oscillometric blood pressure maximum storage over 600 measurements measurement range blood pressure 30 260 mmHg 4 35 kPa pulse 40 200 beat minute passive accuracy 3mmHg 0 4 kPa or 2 of m...

Page 22: ...tient did not wear the cuff device error E90 device error The device could not measure due to a hardware error E99 device error The device does not start automatic measurement until the next programmi...

Page 23: ...accept for repair potentially infectious products or accessories especially pouches and cuffs that might have been in direct contact with the patient and could not be or potentially were not properly...

Page 24: ...ments Note that any blood pressure recording may be affected by the body position the physiological condition of the patient and other factors No user serviceable parts inside Meditech recorders conta...

Page 25: ...ected against splash vertically in a max of 15 degrees This protection refers only to BP5 and BB5 SN YYYY nnnnn Serial number The first four digits of the serial number of a recorder show the year of...

Page 26: ...in domestic establishments and in establishments directly connected to the low voltage power supply network which supplies buildings used for domestic use Harmonic emission IEC61000 3 2 Not applicable...

Page 27: ...power disclosed by the manufacturer of transmitter W and d is the recommended separation distance m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey1 a should...

Page 28: ...wer of the transmitter W 150KHz 80MHz d 3 5 V1 P 80MHz 800MHz d 3 5 E1 P 800MHz 2 5GHz d 7 E1 P 0 01 Not applicable 0 12 0 23 0 1 Not applicable 0 38 0 73 1 Not applicable 1 2 2 3 10 Not applicable 3...

Reviews: