Meditech ABPM-05 User Manual Download Page 22

 

BP5BB5LR_UMEN_V05-20170703 

 

22 

 

Error codes 

Error code 

Explanation 

measurement error 

E1: aborted measurement 

The measurement timeout is over, the 
measurement had to be aborted (the patient 
was moving) 

E2: manually interrupted 

The measurement was stopped by pressing 
a button. The display differs from others: 
"OFF" on the LCD. 

E3: battery rundown 

The batteries exhausted during 
measurement. 

E4: batteries replaced 

The batteries were replaced during 
measurement. 

E8: pressure limit exceeded 

The pressure in the pneumatic system 
exceeded the preset pressure limit 

E9: temporary disturbance 

External electric signal - static discharge - 
disturbed the operation of the device. 

cuff error

 

E31: cuff missing or loose 

There was no cuff connected to the device 
or the cuff was too loose on the patient's 
arm. 

E32: cuff tubing clogged 

The cuff is clogged or the rubber tube is 
broken. 

E33: cuff leaking or loose 

There is a hole in the cuff or it is rather 
loose on the patient's arm. 

E34: cuff not on arm 

The patient did not wear the cuff. 

device error

 

E90: device error  

The device could not measure due to a 
hardware error. 

E99: device error  

The device does not start automatic 
measurement until the next programming. 

 

Meditech product warranty information 

RECORDER  WARRANTY.  The  main  recorder  unit  will  be  free  from  defects  in 
materials  and  workmanship  under  normal  use  and  service  for  a  period  of  two  (2) 
years  from  the  date  of  receipt.  This  warranty  covers  the  recorder  unit  only.  This 
warranty does not cover any accessories that might come with the recorder unit. 
 
ACCESSORIES  WARRANTY.  The  non-disposable  accessories  delivered  with  the 
recorder unit will be free from defects in materials and workmanship under normal 
use and service for a period of one (1) year from the date of receipt. This warranty 
does  not  cover  disposable  accessories,  packaging  materials,  accumulators  and 
batteries, cuffs, or any of their components. 
 
CUFF WARRANTY. The cuff(s) - if delivered with a recorder unit -  will be free from 
defects in materials and workmanship under normal use and service for a period of 
six  (6)  months  from  the  date  of  receipt.  This  warranty  covers  the  cuff(s)  delivered 
with a recorder unit exclusively. 

Summary of Contents for ABPM-05

Page 1: ...User Guide ABPM 05 BlueBP 05 Ambulatory Blood Pressure Monitors...

Page 2: ...11 7 Customize review print data 12 ABPM 05 manual programming 12 Patient information 13 Cuffs 14 Dimensions 14 Application 15 Batteries 16 Safety concerns 17 Cleaning protection 18 Maintenance 19 Dis...

Page 3: ...surge for reliable hypertension management and control Both ambulatory blood pressure monitors incorporate an algorithm validated to BHS British Hypertension Society and AAMI Association for the Advan...

Page 4: ...tion during measurement current pressure is displayed mmHg The device is switched off Systolic value of just completed measurement mmHg The blood pressure measurement is cancelled by pressing a button...

Page 5: ...Heart symbol blinking measurement in progress kPa Diastolic value of a just completed measurement kPa Buttons The monitor has 3 buttons start event and day night Any blood pressure measurement can be...

Page 6: ...event marker in a diary Day night button functions Marking the time of sleeping and awakening If the day night shift function is disabled during programming the patient can press the day night button...

Page 7: ...k and basic solutions 2 Setup the monitor 2 1 Install 2 AA batteries into the monitor Accumulator voltage should be over 2 5V To check press the Start button for at least 5 seconds 2 2 Setup communica...

Page 8: ...unit converts optical signals to electric ones and vice versa The twin optical cable transfers optical signals between the interface unit and the recorder The cable is flexible but it is sensitive to...

Page 9: ...PM 05 select the type of your interface unit select the required port or simply click on Test EasyABPM Device Read data BlueBP 05 If you want to use a BlueBP 05 with Bluetooth under Windows XP SP 2 fo...

Page 10: ...corder in case of BlueBP 05 is BB5_xxxx where xxxx is the last four digits of the serial number found on the back of the recorder After selecting the appropriate recorder the OK button becomes active...

Page 11: ...atient a sample is available on the installation CD and inform the patient about the goal and the expected results of the monitoring and about the use of the monitor 6 Retrieve data 6 1 Remove the uni...

Page 12: ...ght time Other settings are the same in all the three plans undecided cuff size 300 mmHg pressure limit LCD display enabled manual day night shift disabled Daytime starts at 6 00 while nighttime start...

Page 13: ...minute day night intervals 1 measurement plan 15 30 minute day night intervals Programming is in progress blinking signal Patient Information Wearing a thin shirt under the cuff is recommended It does...

Page 14: ...Event button the patient can mark events e g taking medication etc The time of going to and rising from bed can be marked by the Day night button Should the batteries run down during a monitoring ses...

Page 15: ...he cuff is placed above the brachial artery if possible Contrary to the usual placement with the tube pointing downwards the advantage is that the patient can wear a loose jacket over the cuff When pr...

Page 16: ...ult in measurement error and or in certain cases it causes damage to the main recorder unit Batteries Meditech ABPM 05 and BlueBP 05 operate either with two 1 5V AA normal batteries or with two 1 2V A...

Page 17: ...sion they can be replaced Monitoring will continue and data will not be lost Remove the batteries if the recorder is out of use If you do not use the recorder it is advisable to remove batteries since...

Page 18: ...ors are not specially protected against spills or ingression of water or other liquids Cleaning the monitor A recommended means of cleaning is to wipe the recorder with a disinfectant cleaning tissue...

Page 19: ...itech Ltd see relevant topic This warranty does not cover any malfunction or defects arising from improper use the use of inadequate accessories accident theft or use of the device outside operating e...

Page 20: ...ldren without supervision or children younger than 8 years Though the blood pressure measurement algorithm used in the monitors has been found to function properly on patients with atrial fibrillation...

Page 21: ...rement method oscillometric blood pressure maximum storage over 600 measurements measurement range blood pressure 30 260 mmHg 4 35 kPa pulse 40 200 beat minute passive accuracy 3mmHg 0 4 kPa or 2 of m...

Page 22: ...tient did not wear the cuff device error E90 device error The device could not measure due to a hardware error E99 device error The device does not start automatic measurement until the next programmi...

Page 23: ...accept for repair potentially infectious products or accessories especially pouches and cuffs that might have been in direct contact with the patient and could not be or potentially were not properly...

Page 24: ...ments Note that any blood pressure recording may be affected by the body position the physiological condition of the patient and other factors No user serviceable parts inside Meditech recorders conta...

Page 25: ...ected against splash vertically in a max of 15 degrees This protection refers only to BP5 and BB5 SN YYYY nnnnn Serial number The first four digits of the serial number of a recorder show the year of...

Page 26: ...in domestic establishments and in establishments directly connected to the low voltage power supply network which supplies buildings used for domestic use Harmonic emission IEC61000 3 2 Not applicable...

Page 27: ...power disclosed by the manufacturer of transmitter W and d is the recommended separation distance m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey1 a should...

Page 28: ...wer of the transmitter W 150KHz 80MHz d 3 5 V1 P 80MHz 800MHz d 3 5 E1 P 800MHz 2 5GHz d 7 E1 P 0 01 Not applicable 0 12 0 23 0 1 Not applicable 0 38 0 73 1 Not applicable 1 2 2 3 10 Not applicable 3...

Reviews: