Medist MEVACS M90 User Manual Download Page 4

 

 

 

 

 

 

 
UP MEVACS M90 - D4O-0085-2-0 / 13.1.2009 

 

 

T-QN-04/05-01-1

 

 

4 / 15 

Contents 

 
 

1. INTRODUCTION ...................................................................................................................................................5

 

1.1.

 

A

REAS OF USE

.....................................................................................................................................................5

 

2. EQUIPMENT ..........................................................................................................................................................5

 

2.1.

 

B

ASIC EQUIPMENT

...............................................................................................................................................5

 

2.2.

 

S

UPPLEMENTING EQUIPMENT

..............................................................................................................................5

 

2.3.

 

S

AMPLE OF SOME VERSION SUCTION UNIT

: ..........................................................................................................6

 

3. INSTALLATION ....................................................................................................................................................7

 

3.1.

 

U

NIT LOCATION

...................................................................................................................................................7

 

4. PRODUCT DESCRIPTION ..................................................................................................................................8

 

4.1.

 

S

YMBOLS DESCRIPTION

.......................................................................................................................................8

 

5.

 

U

NIT INTERCONNECTION

........................................................................................................................................9

 

5.1.

 

I

NTERCONNECTION OF THE UNIT WITH BASIC EQUIPMENT

...................................................................................9

 

6. SWITCHING ON AND OPERATION .................................................................................................................9

 

6.1.

 

S

UCTION UNIT OPERATIONAL SET

-

OUT

................................................................................................................9

 

6.2.

 

V

ESSEL PREPARATION FOR SECRET

.....................................................................................................................9

 

6.3.

 

S

WITCHING ON

..................................................................................................................................................10

 

6.4.

 

F

UNCTIONAL EXAMINATION OF SUCTION UNIT

..................................................................................................10

 

6.4.1. Inner suction circuit ..................................................................................................................................10

 

6.4.2. Outer suction circuit..................................................................................................................................10

 

6.5.

 

C

HANGING OF THE SECRET VESSEL

....................................................................................................................11

 

6.6.

 

C

HANGING OF BACTERIOLOGIC FILTER

..............................................................................................................11

 

7. TECHNICAL DATA ............................................................................................................................................12

 

8. BASIC MAINTENANCE AND CLEANING .....................................................................................................12

 

8.1.

 

U

NIT ATTENDING AND CLEANING

......................................................................................................................12

 

8.2.

 

S

MALL FAULTS CORRECTION

,

 UNIT TROUBLE SHOOTING

...................................................................................13

 

8.3.

 

R

EGULAR CHECK

...............................................................................................................................................14

 

9. MAIN ASSEMBLIES, SUBASSEMBLIES, COMPONENTS AND SPARE PARTS ....................................14

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MEVACS M90

Page 1: ...IST s r o Petrusovskeho 4 066 01 Humenne Slovakia T Fax 00421 57 7753276 E mail medist medist sk http www medist sk T QN 04 05 01 1 2070 Medical electric suction unit Ordering number MEVACS M90 72001...

Page 2: ...service extension are made by MEDIST company or authorized service organizations the device is used in accordance with this instruction manual Use only microbiological filters supplied by manufacture...

Page 3: ...lectric mains when unplugged from the unit socket Attendant must make certain before every use of suction unit about its good condition and device ready Don t expose the collection vessels for direct...

Page 4: ...H BASIC EQUIPMENT 9 6 SWITCHING ON AND OPERATION 9 6 1 SUCTION UNIT OPERATIONAL SET OUT 9 6 2 VESSEL PREPARATION FOR SECRET 9 6 3 SWITCHING ON 10 6 4 FUNCTIONAL EXAMINATION OF SUCTION UNIT 10 6 4 1 In...

Page 5: ...drophobic bacteriological filter 11 Protection of the unit personnel and patient against infection by means of fitted bacteriologic filter 12 The possibility of all functions operation by means of foo...

Page 6: ...ssure fit lid and metal tubing nipple 42011 12 15 4 0 L jar TM polysulfone with pressure fit lid and metal tubing nipple 42011 10 16 MONOVAC suction liner capacity 1 4 L 42002 01 17 EURO universal rai...

Page 7: ...x 2 0Lit jar MEVACS M90 2 x 4 0Lit jars 2 x 2 0Lit jars MEVACS M90 2 x 4 0Lit jars 1 x 2 0Lit jar foot switch 3 Installation The MEVACS suction unit is a compact unit There is no needed assembly 3 1 U...

Page 8: ...els with brake 8 foot control 9 change valve 10 microbiologic hydrophobic filter 11 EURO rail adapter 12 safety jar 13 safety overflow valve 14 hose connector for connection of vacuum branch 15 safety...

Page 9: ...safety valve is under connector it is labelled as VACUUM 7 Shift the suction hose 11 on the input connector 13 without safety valve of the collecting jar it is labelled as PATIENT 6 Switching on and...

Page 10: ...acuum 6 4 Functional examination of suction unit 6 4 1 Inner suction circuit turn the suction unit on cover the connector 1 on the suction unit by your finger turn the vacuum regulating vent with the...

Page 11: ...removed during clearing 6 6 Changing of bacteriologic filter Suction microbiologic filter eliminated risk of contamination with bacteria viruses and infected particle from patient to suction pump or c...

Page 12: ...2 x 2 0 4 0 LT polycarbonate jars with overflow valve Suction Suction tube Silicone 8 x 3 mm 2 0 m Operation Continuous Filtration Hydrophobic suction microbiological filter with very high bacterial...

Page 13: ...protect together suction unit for overflow secretion The plastic case holders truck and other equipment can be cleaned with soft wet cloth moistened by cleaning agent which does not react with the pl...

Page 14: ...ied faults contact either qualified persons of service company or directly the manufacturer MEDIST s r o Petrusovskeho 4 066 01 Humenne Slovakia tel fax 00421 57 7753276 E mail medist medist sk 8 3 Re...

Page 15: ...2 0 L jar TM with screw metal lid polycarbonate autoclavable 121 O C No 42011 14 polysulfone autoclavable 134 O C No 42011 21 safety valve in lid metal connectors 4 0 L jar TM with pressure fit lid p...