3 Getting Started

GB  

WARNING
BATTERY SAFETY INFORMATION

• Do not disassemble batteries!
• Remove discharged batteries from the device

immediately!

• Increased risk of leakage, avoid contact with skin,

eyes and mucous membranes! If battery acid comes
in contact with any of these parts, rinse the affec
ted area with copious amounts of fresh water and
seek medical attention immediately!

• If a battery has been swallowed seek medical

attention immediately!

• Replace all of the batteries simultaneously!
• Only replace with batteries of the same type,

never use different types of batteries together
or used batteries with new ones!

• Insert the batteries correctly, observing the

polarity!

• Remove the batteries from the device if it is not

going to be used for an extended period!

• Keep batteries out of children's reach!
• Do not attempt to recharge these batteries! There

is a danger of explosion!

• Do not short circuit! There is a danger of explosion!
• Do not throw into a fire! There is a danger of

explosion!

• Do not throw used batteries into the household

refuse; put them in a hazardous waste container
or take them to a battery collection point, at the
shop where they were purchased!

3.2  Using a Mains Adaptor

Alternatively, you can use the unit with a special mains adaptor (MEDISANA
Art.–No. 51036) This connects 

to the socket provided at the back of the unit.

In this case the batteries remain in the unit.
Inserting the connector into the back of the blood pressure monitor switches the
batteries off mechanically. It is necessary, therefore, to plug the mains adaptor into
the mains socket first of all and then to connect it to the blood pressure monitor.
If the blood pressure monitor is no longer being used, first remove the connector
from the blood pressure monitor and then pull the mains adaptor out of the mains
socket. Doing this means that the date and time will not have to be reset each
time.

The display showing the year will flash after inserting the batteries for the first
time. Set the date and time as described in 

3.3 Set Date and Time

. Please note

that the date and time will have to be reset each time new batteries are inserted.
Previously stored results will be lost. 

51047_MTP_MiniFormat_NEUSS19.qxd:OA-Blutdruckmessgerät  06.06.2012 

Summary of Contents for 48681

Page 1: ...Art 48681 GB Upper arm blood pressure monitor MTP Instruction Manual Please read carefully...

Page 2: ...struction Manual 1 Safety Information 1 2 Useful Information 3 3 Getting started 5 4 Operation 7 5 Memory 8 6 Miscellaneous 9 7 Warranty 12 51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06...

Page 3: ...nd controls DC 6V 51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06 2012 GB Upper arm cuff with hose START button Display MEMORY button TIMER button Socket for mains adaptor Connector for t...

Page 4: ...51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06 2012...

Page 5: ...ent any injury to the user CAUTION These notes must be observed to prevent any damage to the device NOTE These notes give you useful additional information on the installation or operation Classificat...

Page 6: ...This exercise optimizes the pulse wave and the measuring process 1 2 Important considerations The unit is only to be used for the specific purpose described in this instruction imanual Any misuse wil...

Page 7: ...ging material no longer required If you notice any transport damage during unpacking please contact your dealer without delay WARNING Please ensure that the polythene packing is kept away from the rea...

Page 8: ...d pressure remains undetected it increases the risk of further cardiovascular diseases THEREFORE WE RECOMMEND Take a blood pressure reading daily and on a regular basis even if you are experiencing no...

Page 9: ...emember that the daily values are influenced by several factors Smoking consumption of alcohol drugs and physical exertion influence the measured values in various ways Measure your blood pressure bef...

Page 10: ...nto the household refuse put them in a hazardous waste container or take them to a battery collection point at the shop where they were purchased 3 2 Using a Mains Adaptor Alternatively you can use th...

Page 11: ...uff s air tube to the designated connector on the unit Open up the cuff to a ring and slip it over the bare left upper arm just above the elbow region If wearing tight clothing ensure that the circula...

Page 12: ...he first to be deleted 5 2 Displaying stored results Press the MEMORY button to display the stored readings Initially the average marked A of all readings in the memory selected is displayed When the...

Page 13: ...ssure has been detected Cause the arm was moved during the measurement Repeat the measurement keeping your arm still ERR 3 If the cuff takes too long to inflate it is possible that the cuff is incorre...

Page 14: ...nces at a municipal or commercial collection point so that they can be dis posed of in an environmentally acceptable manner Remove the batteries before disposing of the device unit Do not dispose of o...

Page 15: ...ns Dimensions Cuff size Weight Article number EAN number Accessories 40 200 beats min 3 mmHg 5 of the reading Automatic using micro pump Automatic After approx 1 minute 10 C to 40 C 15 85 humidity 5 C...

Page 16: ...the unit or for the replacement parts 4 The following is excluded under the warranty a All damage which has arisen due to improper treatment e g nonobser vance of the user instructions b All damage w...

Page 17: ...51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06 2012...

Page 18: ...MEDISANA GmbH Jagenbergstra e 19 41468 NEUSS GERMANY 48681 04 2019 Ver 1 0 51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06 2012...

Reviews: