2.4  Why should you take your blood pressure at home?

MEDISANA

has had many years of experience in the field of blood pressure

measurement. The high precision of 

MEDISANA

devices has been confirmed by

extensive clinical tests, carried out according to strict international standards. One
strong argument in favour of taking blood pressure at home is the fact that the
readings are taken in familiar surroundings under relaxed conditions. The most
important reading is the socalled „baseline value“, the one taken before breakfast,
directly after getting up in the morning. As far as it is possible, you should always
try to take your blood pressure at the same time and under the same conditions
each day.
This ensures comparable results and helps in detecting the first signs of high blood
pressure. If high blood pressure remains undetected, it increases the risk of further
cardiovascular diseases.

THEREFORE WE RECOMMEND:

Take a blood pressure reading daily and on a regular 
basis, even if you are experiencing no apparent 
complaints.

2.5  Blood pressure classification

The following table shows the classification of high and low blood pressure, with-
out taking age into consideration. This blood pressure assessment scale corresponds
to the guidelines of the World Health Organisation (WHO).

Low blood pressure  Normal blood pressure

systolic <100 

systolic 100 – 139

diastolic <60 

diastolic 60 – 89

Types of high blood pressure

mild  

medium  

serious

hypertension

hypertension

hypertension

systolic 140 – 159 

systolic 160 – 179 

systolic >

_180

diastolic 90 – 99 

diastolic 100 – 109 

diastolic >

_110

WARNING

Blood pressure that is too low represents just as 
great a health risk as blood pressure that is too high! 
Fits of dizziness may lead to dangerous situations 
arising (e.g. on stairs or in traffic)!

51047_MTP_MiniFormat_NEUSS19.qxd:OA-Blutdruckmessgerät  06.06.2012 

Summary of Contents for 48681

Page 1: ...Art 48681 GB Upper arm blood pressure monitor MTP Instruction Manual Please read carefully...

Page 2: ...struction Manual 1 Safety Information 1 2 Useful Information 3 3 Getting started 5 4 Operation 7 5 Memory 8 6 Miscellaneous 9 7 Warranty 12 51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06...

Page 3: ...nd controls DC 6V 51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06 2012 GB Upper arm cuff with hose START button Display MEMORY button TIMER button Socket for mains adaptor Connector for t...

Page 4: ...51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06 2012...

Page 5: ...ent any injury to the user CAUTION These notes must be observed to prevent any damage to the device NOTE These notes give you useful additional information on the installation or operation Classificat...

Page 6: ...This exercise optimizes the pulse wave and the measuring process 1 2 Important considerations The unit is only to be used for the specific purpose described in this instruction imanual Any misuse wil...

Page 7: ...ging material no longer required If you notice any transport damage during unpacking please contact your dealer without delay WARNING Please ensure that the polythene packing is kept away from the rea...

Page 8: ...d pressure remains undetected it increases the risk of further cardiovascular diseases THEREFORE WE RECOMMEND Take a blood pressure reading daily and on a regular basis even if you are experiencing no...

Page 9: ...emember that the daily values are influenced by several factors Smoking consumption of alcohol drugs and physical exertion influence the measured values in various ways Measure your blood pressure bef...

Page 10: ...nto the household refuse put them in a hazardous waste container or take them to a battery collection point at the shop where they were purchased 3 2 Using a Mains Adaptor Alternatively you can use th...

Page 11: ...uff s air tube to the designated connector on the unit Open up the cuff to a ring and slip it over the bare left upper arm just above the elbow region If wearing tight clothing ensure that the circula...

Page 12: ...he first to be deleted 5 2 Displaying stored results Press the MEMORY button to display the stored readings Initially the average marked A of all readings in the memory selected is displayed When the...

Page 13: ...ssure has been detected Cause the arm was moved during the measurement Repeat the measurement keeping your arm still ERR 3 If the cuff takes too long to inflate it is possible that the cuff is incorre...

Page 14: ...nces at a municipal or commercial collection point so that they can be dis posed of in an environmentally acceptable manner Remove the batteries before disposing of the device unit Do not dispose of o...

Page 15: ...ns Dimensions Cuff size Weight Article number EAN number Accessories 40 200 beats min 3 mmHg 5 of the reading Automatic using micro pump Automatic After approx 1 minute 10 C to 40 C 15 85 humidity 5 C...

Page 16: ...the unit or for the replacement parts 4 The following is excluded under the warranty a All damage which has arisen due to improper treatment e g nonobser vance of the user instructions b All damage w...

Page 17: ...51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06 2012...

Page 18: ...MEDISANA GmbH Jagenbergstra e 19 41468 NEUSS GERMANY 48681 04 2019 Ver 1 0 51047_MTP_MiniFormat_NEUSS19 qxd OA Blutdruckmessger t 06 06 2012...

Reviews: