Cleaning the optical surfaces 

 
Some of the optical surfaces in your AttaXX system are made for very high reflectivity, such 
as mirror surfaces etc. Reflectivity of more than 98% is obtained only, if the mirror surface is 
free of dirt or fingerprints. Also, lenses and filters depend on a clean surface for maximum 
efficiency.  
 
Unfortunately, a cleaning of the silver mirrors in your AttaXXis only possible once or twice.  
Since the optical section is dust free and also air free, there should not be any contamination 
of these mirrors. During alignment process, and any time, the case top is lifted or unmounted, 
please make sure, to work in a clean environment with minimum dust particles. The lesser 
your particles, the better your results. In the unlikely case of a dirty or contaminated mirror 
surface, you can try to clean the mirror with simple glass cleaner and a very mellow paper 
tissue. Do not use any alcoholic cleaner such as Acetone or Methanol! If cleaning is not 
possible, the mirror has to be exchanged.  
 
Other optical coated surfaces can be cleaned the same way, with standard glass cleaner and a 
mellow paper tissue just as Kodak Lens Paper. Make sure not to leave any traces of the 
cleaner fluid on your surface. Do not rub or press on the surface of the mirrors.  
 
Color filters can also be cleaned easily, since the coating is much harder than the ones on the 
mirrors. Make sure to avoid any rough treatment.  
 
 

Connections and adjustments 
 

The rear panel of the AttaXX shows several connectors and adjustment features. Main control 
of the projector is the ILDA compatible connector. It supports full RGB, differential XY 
signals, and automatic switching between ILDA connector and internal player board, or LAN 
board, if applicable. The pin connection is described on the back of the AttaXX, here is a 
summary:  
 
 
 

Summary of Contents for AttaXX 10 RGB

Page 1: ...phase power The projector comes in different output power versions and dimensions from 2 5W RGB up to 18W RGB or 15W single color green Depending of the optional add ons a different type of galvo scan...

Page 2: ...the devices are more sensitive to external influences than normal lighting devices Please use this manual for basic hints and tricks for maintenance of AttaXX Laser Systems In case of any further help...

Page 3: ...ng on output power and setup of the AttaXX projector different laser modules are used which are coupled and aligned to one single beam But in any case each single color is mixed to one beam before it...

Page 4: ...n try to clean the mirror with simple glass cleaner and a very mellow paper tissue Do not use any alcoholic cleaner such as Acetone or Methanol If cleaning is not possible the mirror has to be exchang...

Page 5: ...tries or other countries with low AC voltage a different fuse might be necessary In this case replace the 2A fuse with a 4A type Scanfail safety circuit All AttaXX projectors are equipped with a fast...

Page 6: ...60555 2 1987 DIN EN 60555 3 1987 Furthermore the device is verified in correspondence to the laser class regulations DIN EN 60825 1 if properly set up according to the upper mentioned laser safety reg...

Page 7: ...lized or switched power supply The MicroAmp is able to run between 20VDC to 30VDC at 1 5A each The speed between 20V and 30V is different especially at small step angles While MediaLas uses mainly 30V...

Page 8: ...s are needed For this the ILDA test pattern is used also a setup of the galvos in XY with a laser If the driver is totally deadjusted this will be the procedure to retune it Size Servo Gain Damping un...

Page 9: ...with the attached heatsink If you want to save space remove the heatsink and mount the amp on a metal housing to remove the heat from the power stage The temperature at the heatsink should be below 7...

Page 10: ...uses blow continously do not replace them with a higher value Check for possible errors The maximum current per phase should be in average below 700mA If it is higher there can be a problem which can...

Page 11: ...tensity output with 8bit resolution Scanspeed up to 200 000 pps Full compatible ILDA output connector Simple supply voltage of 12VDC 500mA Replaces USB interface NetPort replaces the common HyperPort...

Page 12: ...trol Note The value is equal to the fader value for show selection To make control via fader more easy 2 different DMX channels are used for show selection each one for 16 numbers Both channels are mu...

Page 13: ...u get back into the show table Note If your browser support these only the first frame in sequence can be displayed in the preview If there is no content in the first frame the preview picture will re...

Page 14: ...uence number 1 to 16 while High selects a multiplier of 1 to 16 So 16 x 16 256 sequences can be started by use of the 2 channels If one DMX channel is just available deselect Showselect High Only 16 s...

Page 15: ...A value of 127 is the neutral position Rotation Rotates the projection up to 1 turn values 0 and 255 are equal Note that the picture may be cropped at maximum projection angle for example if a full s...

Reviews: