15
Size (X) und Size (Y)
Size control for both projection axes X and Y individual.
The difference to 'Size' is that 255 is the maximum, 115-140 is minimum (10%) and values
below 115 are inverting the display of the axis.
This can be used to invert orientation of the projected image.
Offset (X) und Offset (Y)
An offset to the position of the picture.
At maximum size, a picture may be cropped at the edge, when an offset is added.
25
Shear (X) und Shear (Y)
This is a geometrical correction. It is normally not necessary to control this parameter via
DMX.
This parameter is necessary to correct projection when projecting to a flat screen from a side
position. A value of 127 is the neutral position.
Rotation
Rotates the projection up to 1 turn. values 0 and 255 are equal.
Note that the picture may be cropped at maximum projection angle (for example if a full size
square is rotated).
Keystone (X) und Keystone (Y)
These are also geometrical corrections and are necessary to compensate distortion of the
picture caused by projection from a side position to a flat screen.
Intensity
Currently not supported.
Note:
Geometrical corrections to compensate distortions caused by projection from side
position should be set to DMX-control first to find out the right parameter value.
After adjusting the right values, these values then can be set as fixed values in the table, and
DMX control for this function can be deactivated.
All these parameters have no effect on live operating mode (LAN-control) via host-PC.