20
© 05.2022
10 Replacement and Disposal
After the device has reached the end of its useful life, it must be dismounted and disposed of in an environmentally
friendly manner.
During dismounting, components that may present a risk of injury by contamination,
depending on the medium, are removed. The components must be properly decontaminated depending
on the processed medium. Diffusible components (diaphragm, O-ring, etc.) may have to be taken
to a special disposal unit, depending on the medium used.
If no return or disposal agreement has been signed, disassembled components should be recycled:
•
Metals should be scrapped
•
The remaining components should be disposed of after sorting according to material.
For technical information, please contact our customer service:
MEDENUS
©
Gas-Druckregeltechnik GmbH
Im Langen Feld 3
D-57462 Olpe
Phone +49 (0) 2761 / 82788-0
Fax +49 (0) 2761 / 82788-9
E-mail [email protected]
Internet www.medenus.de
ATTENTION
11 Spare Parts
11.1 Parts for Maintenance Work
O-rings
Item
no.
Name
Quantity
pcs.
Variant
exception/
version
R51 / 025
4
O-ring
1
O-013
7
O-ring
1
O-006
11
O-ring
1
O-007
17
O-ring
1
O-008
20
O-ring
1
O-013
2
HD2
O-013
O-ring set
order number:
OS-061
Example:
Gas pressure regulator: R51 / 025
Spare parts according to tables in 11.1
Valve plate:
VT-012
Diaphragm:
M-001
Diaphragm:
M-111
O-ring and sealing ring set:
OS-061
Info:
The allocation of individual parts is done according to the item no. in the tables in 11.1, conforming to the
spare parts sectional view in 11.2.
Valve Plates / Diaphragms
Item
no.
Name
Quantity
R51 / 025
6
Valve plate
1
VT-012
12
Diaphragm
1
M-001
16
Diaphragm
1
M-111
In addition, we are always interested in information, suggestions and experience resulting from the application and
which can be valuable for improving our products.
Note