12.0  Limited Warranty

For all Silverlight products unless otherwise specified.
Any non-approved usage of the Silverlight device and accessories will void the warranty.
Any usage of non-Silverlight parts, components/accessories or procedures will void the warranty.
The manufacturer, Mectron S.p.A., warrants to the first original purchaser (customer) that their products 
have been tested, inspected and shipped in proper working order.
All Silverlight products are covered by warranty for a period of one year from the date of purchase.
Products are warranted to be free from defects in material and workmanship.
This limited warranty does not apply to any unit/accessory which has been subject to abnormal wear 
and tear, misuse, abuse, neglect, improper installation or operation or that has been altered, adjusted or 
tampered with by any person other than GC America Inc. authorized personnel.
The warranty is valid only if GC America Inc. is notified within thirty (30) days following discovery of a 

defect.

For returning procedure make reference to the paragraph “CUSTOMER SERVICE – RETURNS”
Returns must be authorized by GC America Inc.
GC America Inc. cannot accept responsibility for returns which have not been authorized.
Contact GC America Inc. Customer Service at 800-323-7063 for return authorization.

GC America Inc. will investigate and shall correct any defect covered by warranty by providing a replace

-

ment of the product.

If upon examination by GC America Inc.’s service personnel it is determined that the malfunction is caused 
by abnormal wear and tear or by damage caused by misuse, abuse, tamper with, or by failure to perform 
normal and routine maintenance as set out in the instructions for use and maintenance booklet provided 
with the unit, warranty provisions will not apply.

GC America Inc will not replace or repair any product or part of the product after the warranty period (one 
year from date of purchase) has expired.

Summary of Contents for Silverlight

Page 1: ...Manual of use and maintenance...

Page 2: ...l 10 05 4 Battery failed signal 10 05 5 Battery problems 10 05 6 Safety requirements relating to the battery 10 06 0 Use 11 06 1 Connecting the accessories 11 06 2 Safety requirements during use 12 06...

Page 3: ...dated to the date of publication indicated on the last page The manufacturer Mectron S p A is committed to continuous updating of products which may entail changes to components of the equipment If th...

Page 4: ...Do not use this equipment on patients fitted with pace makers or any other implantable electronic devices This requirement applies equally to the operator DANGER Point the beam of light directly at t...

Page 5: ...R Do not install the equipment anywhere there is a risk of explosions The equipment cannot function in places where there is an inflammable atmosphere anesthetic mixtures oxygen etc DANGER Do not use...

Page 6: ...re ensures proper functioning and reliability of all components 03 0 Delivery 03 1 Delivery of the device The equipment contains electronic components that may be damaged by impacts even inside the pa...

Page 7: ...verlight recharging unit Fig 3 Ref A B Silverlight handpiece with rechargeable lithium ion battery Fig 3 Ref B C Fiber optic Fig 3 Ref C D Optical protection Fig 3 Ref D E Power supply cable for the r...

Page 8: ...GER Do not short circuit the electric contacts of the recharging unit with metal objects Fig 5 Ref B and do not touch them with your hands while the apparatus is switched on WARNING The apparatus is t...

Page 9: ...aced on the recharging unit the green battery LED does not switch on This is normal Description of the acoustic signals of the handpiece Table 2 Function Push button control Acoustic signal FAST polym...

Page 10: ...eck the battery continuously and maintain the optimum battery charging parameters The handpiece may therefore be placed back into the recharging unit at the end of each treatment and left there regard...

Page 11: ...wer LED will light up 05 5 Battery problems To replace a failed battery contact GC America Inc Customer Service Do not attempt to open remove change replace or in any other way adjust the battery Thes...

Page 12: ...circuit the battery terminals This could cause burns and fire 06 0 Use 06 1 Connecting the accessories DANGER Check the condition of the device before the treatment Before each treatment always make s...

Page 13: ...t efficient this will reduce the intensity of the light being emitted considerably In such cases it should therefore be replaced 06 3 Instructions for use The silverlight can be used in two different...

Page 14: ...the working luminous flux measured Green luminous flux suitable for effective treatment Red luminous flux insufficient WARNING If the working luminous flux is not sufficient do not proceed with the t...

Page 15: ...fection disconnect the recharging unit from the main power supply DANGER The casing of the recharging unit is not protected against the entry of liquids DANGER Do not spray liquids directly onto its s...

Page 16: ...ilization procedures dry heat radiation ethylene oxide gas low temperature plasma etc DANGER The handpiece and recharging unit must not be sterilized DANGER Infection control Sterilizable parts To avo...

Page 17: ...he battery must be disposed of and treated as waste requiring separate collection This equipment must be disposed of and treated as waste requiring separate collection Dispose of unserviceable batteri...

Page 18: ...is ON Battery failed Contact GC America Inc Customer Service See point 05 4 and 05 5 There is no beam of light when the push button of the Silverlight is pressed and an acoustic signal is heard two be...

Page 19: ...ed in transparent quartz Sterilizable by steam autoclave Minimum sterilization parameters Three times pre vacuum cycle at 132 C for 4 minutes Drying time 10 minutes max temp 135 C max 500 cycles Expos...

Page 20: ...environment Guidance RF emissions CISPR 11 Group 1 The Silverlight uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference i...

Page 21: ...ins power qual ity should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power qual i...

Page 22: ...gths from fixed RF transmit ters as determined by an electromagnetic site survey a should be less than the com pliance level in each frequency rangeb Interference may occur in the vicinity of equipmen...

Page 23: ...er of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1...

Page 24: ...her than GC America Inc authorized personnel The warranty is valid only if GC America Inc is notified within thirty 30 days following discovery of a defect For returning procedure make reference to th...

Page 25: ...the equipment in its original packaging to ensure it is not damaged during shipment DANGER All the products must be cleaned and sterilized before returning GC America Inc will not accept and process p...

Page 26: ...063 Fax 800 GCFAXME Caution US Federal Law restricts this device to sale by or on the order of a dentist silverlight V USA Rev 01del 02 18 2010 manufacturer Mectron S p A Via Loreto 15 A 16042 Carasco...