9
DELIVERY
3
DELIVERY
3.1
List of the Components of PIEZOSURGERY® GP
Refer to the front endpaper.
PIEZOSURGERY® GP consists of:
A. Device core system;
B. Peristaltic pump;
C. Irrigation bag support rod;
D.
PIEZOSURGERY® GP handpiece fixed
holder;
E. Use and Maintenance Manual, Cleaning
and Sterilization Manual;
F. Power Cord;
G. Foot pedal with cable and connector;
H.
Back-up foot pedal;
I.
K8 Mectron torque wrench;
J. Peristaltic pump tubing kit (The kit is
composed by a set of 6 peristaltic pump
tubing);
K. Case.
The following components/accessories are
sold separately from the PIEZOSURGERY® GP
device:
CAUTION:
The handpiece and the cord
cannot be separated.
NOTE:
The stainless-steel box supplied with
the Piezosurgery handpiece is intended
exclusively for transportation, from the
working area to the decontamination area
and
NOT
for the sterilization process.
L. PIEZOSURGERY® handpiece complete
with cord (with or without LED light);
M. PIEZOSURGERY® GP handpiece
movable holder;
N. Bone grafting kit;
O.
Inserts/insert kit.
NOTE:
Some inserts require specific
accessories and tools for being correctly
used (for example kits and / or dedicated
torque wrenches). Always read and follow the
assembly and cleaning instructions supplied
with the insert.
PIEZOSURGERY® GP consists of accessories
that can be ordered separately. Refer to the
“Packing List” included in your package, so
that you may exactly know the quantity and
type of the accessories supplied with the
device you have purchased.
The packaging of the device cannot undergo
strong impacts as contains electronic
components, therefore the transport and the
storage must be carried out with particular care.
Do not stack more boxes in order to avoid
damaging the underlying packaging.
All material shipped by Piezosurgery Inc. is
controlled at the time of dispatch.
The device is shipped appropriately protected
and packaged.
Upon receipt of the device, check for any
possible damage caused during transport and
in case any damage and/or defects is found,
complain to the transporter.
Keep the packaging in case there is a necessity
to send any item to Piezosurgery Inc. Customer
Service and to store the device during long
periods of inactivity.
WARNING
: Before starting to operate
with the device, make sure that you have
stock material (handpiece, inserts, wrenches)
available to use in case the device stops due
to a fault or of inconveniences.