Chapter 1.   INTRODUCTION 

 

Thank you for purchasing Mechline’s HyGenikx

TM

 air & surface steriliser system. When correctly installed, and operated 

in accordance with this Operator Manual, it will provide many years of service. 

HyGenikx is an advanced and compact, wall mounted steriliser system, proven to eradicate viruses and bacteria 

throughout foodservice and hospitality environments, washrooms, changing rooms and beyond. 

Utilising a combination of the most effective air and surface sterilisation technologies available - Germicidal 

Oxidation, Germicidal Irradiation, Dual waveband Plasma Quatro - HyGenikx provides round-the-clock hygiene and 

safety protection, controls odours and has also significantly been proven to prolong the life of fresh perishable foods.  

Mechline’s HyGenikx system has been through rigorous testing, providing customers with the utmost confidence in 

its effectiveness and quality. 

 

 

 

 

LEAVE THIS MANUAL WITH THE OPERATOR AFTER INSTALLATION 

 

INSTALLATION INSTRUCTIONS 

6. 

Unit

 ........................................................................ 

7. 

Lamp and Battery

 .................................................. 

 

INSTALLATION &  

OPERATING MANUAL

Summary of Contents for HyGenikx+ HGX-T-05-O

Page 1: ...is an advanced and compact wall mounted steriliser system proven to eradicate viruses and bacteria throughout foodservice and hospitality environments washrooms changing rooms and beyond Utilising a c...

Page 2: ...eces Noise level 1 metre 39dB Air flow rate 20 m3 hr Suggested coverage 10 30 m2 10 40 m2 Installation Wall mount Housing material Aluminium alloy internal polycarbonate front ABS base Colour Front Wh...

Page 3: ...ness of breath these symptoms should only be short term and be resolved when the individual is removed to fresh air If there are any concerns about the ozone produced please disconnect power to the un...

Page 4: ...s section 3 2 5 Before attempting servicing or maintenance tasks the unit MUST be isolated from the power source and disconnected 3 2 6 Should a fault occur with the unit immediately isolate and disco...

Page 5: ...d H On Off indicator light Chapter 5 LOCATION ADVICE For general advice refer to Section 9 4 11 The unit should be placed in a ventilated area Some initial odour caused by the electrical components wi...

Page 6: ...k and drill holes using template provided on packing box 6 1 4 Insert wall plugs into drilled holes Use hammer to fit wall plugs into position Insert screws provided into wall plugs and screw into pos...

Page 7: ...nce of the system If the indicator light shown in Chapter 4 as part P in the diagram is flashing and an audible alarm is heard it is time for the lamp and battery to be replaced 7 2 LAMP AND BATTERY R...

Page 8: ...ch unit Is the indicator illuminated on unit front with lamp light also visible through the vents of unit If not please refer to Section 9 3 Lamp Unit Failure Checklist Is there an odour present in th...

Page 9: ...and BATTERY for 30m 2 GENERAL areas HGX 10 F LAMP ORANGE with food safe shatterproof sheath BATTERY for 10m 2 FOOD SERVICE areas HGX 20 F LAMP BLUE with food safe shatterproof sheath BATTERY for 20m 2...

Page 10: ...ontinuous and not being switched off in error Some locations such as shopping centres have a central switch off 9 2 3 Check the unit location At a minimum height of 1 8 metres units must be wall mount...

Page 11: ...moisture source Increase ventilation of environment Consider switching to a fan powered unit E mail Mechline for further advice 9 3 5 Lamp not pushed fully home can cause short circuits Check and conn...

Page 12: ...use it is not unusual for the unit to produce a slightly metallic odour this is caused by the lamp bedding in This should dissipate within 48 hours 9 4 4 In addition to odours what are the microorgani...

Page 13: ...eak down Volatile Organic Compounds VOCs Interaction of the Dual waveband UV with the TiO2 heterogeneous catalyst both creates and breaks down Oxygen molecules transforming Oxygen into a highly reacti...

Page 14: ...circulation installing the unit as close as is practical to the strong odour or contamination source is recommended i e next to food storage in cold store above preparation areas in kitchen next to u...

Page 15: ...amp and the anodized aluminium air diffuser plates at all These plates are self cleaning Chapter 11 AFTER SALES and SERVICE SUPPORT For technical assistance please contact Mechline technical mechline...

Page 16: ...sociates Material and information included are correct at time of print Intending buyers and users must satisfy themselves as to the suitability and safety of the products for their particular purpose...