background image

 
 
Instruction Manual 

 

 

P-Series Inclinometer

 

 

MEAS Deutschland GmbH 

www.meas-spec.com     

phone: +49-(0)231-9740-0 

Hauert 13, D-44227 Dortmund, Germany  

5 of 16 

fax: +49-(0)231-9740-20 

July 2014 

 

 

4.2  Ordering information 

Measurement Specialties offers single and dual axis inclinometers of the P-series in the three different 
measurement /- 5°, +/- 15° and +/-45° with RS 232, voltage or current output signals. 

 

PART NUMBERING 

UNIT 

 

SHORT DESCRIPTION 

 

Single axis unit 

 
G-NSP-001 

 

NS-5/P   

single axis,   +/-5° angle, Vcc +6.5…24VDC, /-1.5V,RS232   

G-NSPI-001 

 

NS-5/PI   

single axis,   +/-5° angle, Vcc +6.5…24VDC, output 4…20mA,RS232   

G-NSP-002 

 

NS-15/P  

single axis, +/-15° angle, Vcc +6.5…24VDC, /-1.5V,RS232   

G-NSPI-002 

 

NS-15/PI 

single axis, +/-15° angle, Vcc +6.5…24VDC, output 4…20mA,RS232 

G-NSP-005 

 

NS-45/P  

single axis, +/-45° angle, Vcc +6.5…24VDC, /-1.5V,RS232   

G-NSPI-006 

 

NS-45/PI 

single axis, +/-45° angle, Vcc +6.5…24VDC, output 4…20mA,RS232 

 

Dual axis unit 

 
G-NSP2-001 

 

NS-5/P2  

dual axis,   +/-5° angle, Vcc +6.5…24VDC, output RS232   

G-NSP2-003 

 

NS-15/P2 

dual axis, +/-15° angle, Vcc +6.5…24VDC, output RS232   

G-NSP2-006 

 

NS-45/P2 

dual axis, +/-45° angle, Vcc +6.5…24VDC, output RS232   

 

Accessories  
 

G-NSMIS-005 

 

certificate 

certificate of calibration, calibration protocol 

 
G-NSMIS-001 

 

connection 

connector,straight, Submin. 712-series 

G-NSMIS-015 

 

connection 

connector, angle 90°, Submin. 712-series 

 
G-NSMIS-002 

 

connection 

2 m cable, straight connector Submin. 702-series 

G-NSMIS-003 

 

connection 

2 m cable, angle 90° connector Submin .702-series 

 
Other cable lenght on request 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for P-Series

Page 1: ...ies Inclinometer MEAS Deutschland GmbH www meas spec com phone 49 0 231 9740 0 Hauert 13 D 44227 Dortmund Germany 1 of 16 fax 49 0 231 9740 20 July 2014 Instruction Manual Single and Dual Axis Inclinometer P Series Version 1 2 ...

Page 2: ...Connections 7 5 1 Dimensions mm of the Dual Axis Unit 7 5 2 Dimensions mm of the Single Axis Unit 8 5 3 Mounting Instruction 9 5 4 Installation 9 5 5 Measurement Direction 9 5 6 Absolute Maximum Ratings 10 5 7 Electrical Connections 11 5 7 1 Pinning single axis unit with RS 232 voltage output signal NS 5 P NS 15 P NS 45 P 11 5 7 2 Pinning single axis unit with RS 232 current output signal NS 5 PI ...

Page 3: ...o the housing 3 Do not operate an inclinometer beyond the maximum angular sensing range or threshold Irreparable damage may occur 4 Do not exceed the maximum fastening torque for the mounting screws as the base plate may become warped and or irreparably damaged 5 Use detergents free of alcohol or acid for cleaning of the housing 6 Avoid direct solar radiation 7 Hand tightens mating connector DO NO...

Page 4: ...e sensitive axis The chamber is partially filled with an electrolytic liquid When an alternating voltage is passed between two electrodes the electric current will create a dispersed field By tilting the sensor and thereby reducing the level of liquid it is possible to confine this stray field Because of the constant specific conductivity of the electrolytes a variance of resistance is formed in r...

Page 5: ...24VDC output 1 5V RS232 G NSPI 002 NS 15 PI single axis 15 angle Vcc 6 5 24VDC output 4 20mA RS232 G NSP 005 NS 45 P single axis 45 angle Vcc 6 5 24VDC output 1 5V RS232 G NSPI 006 NS 45 PI single axis 45 angle Vcc 6 5 24VDC output 4 20mA RS232 Dual axis unit G NSP2 001 NS 5 P2 dual axis 5 angle Vcc 6 5 24VDC output RS232 G NSP2 003 NS 15 P2 dual axis 15 angle Vcc 6 5 24VDC output RS232 G NSP2 006...

Page 6: ... 712 M9 x 0 5 4 4 Cable Connector Assembly optional Type of cable LiYCY 6 x 0 14mm 2 Conductor resistance 131 Ohm km Capacity 90pF m at 1kHz Length 2m further lengths on request Connector 712 M9 x 0 5 Straight connector order no G NSMIS 002 Angle 90 connector order no G NSMIS 003 Connector only optional Straight connector order no G NSMIS 001 Fig 4 4 1 Connector drawing straight Angle 90 connector...

Page 7: ...www meas spec com phone 49 0 231 9740 0 Hauert 13 D 44227 Dortmund Germany 7 of 16 fax 49 0 231 9740 20 July 2014 5 Dimensions Mounting Electrical Connections 5 1 Dimensions mm of the Dual Axis Unit Fig 5 1 1 View of the dual axis inclinometer housing and connector ...

Page 8: ...AS Deutschland GmbH www meas spec com phone 49 0 231 9740 0 Hauert 13 D 44227 Dortmund Germany 8 of 16 fax 49 0 231 9740 20 July 2014 5 2 Dimensions mm of the Single Axis Unit Fig 5 2 1 View of the single axis inclinometer housing and connector ...

Page 9: ...do not exceed 5 4 Installation Prior to installation please check for all connection and mounting instructions to be complied with Please also observe the general rules and regulations on low voltage technical devices Avoid shock and vibration during measurement as these could adulterate the measurement results Inclination sensors that base on a fluidic measurement principle are optimal for static...

Page 10: ...5 6 Absolute Maximum Ratings Parameter Symbol Conditions Min Typ Max Unit Power supply Vcc Measured Ub to GND No polarity protection 0 28 V Maximum angle φmax NS 5 Px NS 15 Px NS 45 Px Do not exceed maximum angle while under power supply for extended period of time Irreversible drift may occur 15 40 60 15 40 60 Storage temperature Tstor 25 85 C Operation temperature Ta 25 85 C ...

Page 11: ...al GNDx of an inclinometer NS 5 P Notice The signal ground GNDx has not the same potential like the power ground GND Fig 5 6 1 1 X output V vs angle Pin Name Description Type Color schema 1 1 Vcc power supply 6 5 24VDC supply white 2 GND power supply ground RS 232 ground supply brown 3 Earth earth supply green 4 GNDx signal ground for voltage output supply yellow 5 Out x x axis voltage output 1 5V...

Page 12: ...d GNDx has the same potential like power ground GND Measurement range x 20mA 0 12mA x 4 mA Standard impedance Za 160 Ohm special impedance Za 260 Ohm on request Fig 5 6 1 1 X output mA vs angle Pin Name Description Type Color schema 1 1 Vcc power supply 6 5 24VDC supply white 2 GND power supply ground RS 232 ground supply brown 3 Earth earth supply green 4 GNDx signal ground for current output sup...

Page 13: ...nput pink 7 TxD output digital signal RS 232 output blue 5 7 4 Connection Digital Interface RS 232 5 7 4 1 Structure of data string Single axis unit Dual axis unit Baud rate 2400 9600 baud 2400 9600 baud Format ASCII 8 data bits 1 stop bit no parity ASCII 8 data bits 1 stop bit no parity String length 9 byte 22 byte Layout D0 D1 D2 D3 D4 D5 D6 D7 D8 D0 D21 D0 sign or D0 D8 X xx xxx D1 D6 xx xxx D2...

Page 14: ...uously 5 8 1 Commands in user level Default after power on running mode Commands in user level Input Output Comment Setup mode Stop continuous output of inclination values s s s holding pressed stops the continuous output of angle results required for input of commands terminated by e or reset or power on Setup mode Activate P prog P P This command is used to activate the setup mode The password p...

Page 15: ...his command is used to activate zero setting mode to safe the currently position of the unit Offset in 1 1000 x value Notice The zero point can be set only if the current angle is between 5 x 5 The command is ignored if the angle is outside the afore mentioned range The connection to zero can be cancelled by repeatedly inputting the command n factory default Exit e E To closed the zero setting mod...

Page 16: ...Email info cn meas spec com Web www meas spec com The information in this sheet has been carefully reviewed and is believed to be accurate however no responsibility is assumed for inaccuracies Furthermore this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer Measurement Specialties Inc reserves the right to make changes without fu...

Reviews: