Instruction Manual
P-Series Inclinometer
MEAS Deutschland GmbH
www.meas-spec.com
phone: +49-(0)231-9740-0
Hauert 13, D-44227 Dortmund, Germany
14 of 16
fax: +49-(0)231-9740-20
July 2014
5.7.4.3 Connection RS 232 interface PC to inclinometer
PC side
Plug in connector NS-xx/DMG2-x
Sub D-connector 9 pins
7 pin Binder 712-series connector with Meas cable
Pin 2
RxD
1 white +Ub supply positive power supply
Pin 3
TXD
2 brown GND supply negative power supply, ground
Pin 5
GND
3 green Earth supply earth
4 yellow n.c.
n.c.
5 grey n.c.
n.c.
6 pink RxD input Rx digital signal RS 232
7 blue TXD output Tx digital signal RS 232
5.8 Programming Instructions
The P-series has he possibility to programming some parameter to optimize the inclinometer.
This programming instruction is valid for single and duals axis P-series.
A standardized RS232 interface is used in duplex mode.
After startup the sensor transmits the angle values in degrees (°) continuously.
5.8.1 Commands in user level
Default after power on, running mode.
Commands in user
level
Input
Output
Comment
-Setup mode-
Stop continuous output
of inclination values
“s”
“s”
`s` holding pressed, stops the continuous output
of angle results, required for input of commands,
terminated by “e” or reset or power on.
-Setup mode-
Activate
“P”
“prog”
“P?”
“P!”
This command is used to activate the setup
mode. The password `prog` has to be entered
within 3 seconds. If you lose out on, the unit will
be going into the running mode.
Command request
“B?”
After received `B?`, choose the single step, baud
rate setting, zero setting or close the setup
mode.
Exit
“e”
“E!”
To closed the setup mode, press `e´ to go into
running mode or go to another step.
-Single step mode-
Activate
“s”
“S!”
“S?”
This command is used to activate the single step
mode. Change the continuous output of angle
results into polling mode.
Single step activation,
off
“0”
CR,LF
“B?”
The single step activation will be stopped,
off.(default value)
Single step activation,
on
“1”
CR,LF
B?”
The single step activation will be running, on.
Polling mode.
Exit
“e”
“E!”
To closed the single step mode, press `e´ to go
into single step polling.