Instruction Manual
P-Series Inclinometer
MEAS Deutschland GmbH
www.meas-spec.com
phone: +49-(0)231-9740-0
Hauert 13, D-44227 Dortmund, Germany
13 of 16
fax: +49-(0)231-9740-20
July 2014
5.7.3 Pinning dual axis unit with RS232 output signal: NS-5/P2, NS-15/P2, NS-45/P2
Pin
Name Description
Type
Color schema
(1)
1
Vcc
power 6.5...+24VDC
supply
white
2
GND
power supply ground, RS 232 ground supply
brown
3
Earth
earth
supply
green
4
n.c.
n.c.
-
yellow
5
n.c.
n.c.
-
grey
6
RxD
input digital signal RS232
input
pink
7
TxD
output digital signal RS 232
output
blue
5.7.4 Connection Digital Interface RS 232
5.7.4.1 Structure of data string:
Single axis unit
Dual axis unit
Baud rate:
2400(*)/9600 baud
2400(*)/9600 baud
Format:
ASCII, 8 data bits, 1 stop bit, no parity
ASCII, 8 data bits, 1 stop bit, no parity
String
length:
9 byte
22 byte
Layout:
< D
0
,D
1
,D
2
,D3,D4,D
5
,D
6
,D
7
,D
8
>
< D0 ... D21>
D0 = sign(+ or -)
D0 ... D8 =“X“;“=“+(-)“;“xx.xxx“
D1...D6 = “xx.xxx”
D2 = sign (+ or -)
D3 = point
D5 = point
D7 =<CR>
D9 =<CR>
D8 =<LF>
D10 =<LF>
D11 ... D21 =“Y“;“=“+(-)“;“yy.yyy“
D13 = sign (+ or -)
D16 = point
D20 =<CR>
D21 =<LF>
(*) default value
5.7.4.2 Display sample
Inside measurement range
Out of measurement range, overflow
…
…
X=+04.475
X=+++++++ or X=-------
Y=-05.875
Y=+++++++ or Y=-------
2
3
4
5
6
1
7
(1) by using a Measurement Specialties cable