![MDV MDVi-D100Q4/N1-C Manual Download Page 40](http://html1.mh-extra.com/html/mdv/mdvi-d100q4-n1-c/mdvi-d100q4-n1-c_manual_1757515040.webp)
MHVAC-DTSM-2010-03 Capacity
Tables
Four-way Cassette Type (New Designed)
39
7. Capacity Tables
7.1 Cooling
TC
: total capacity
SC
: sensible capacity
WB
: wet-bulb temperature
DB
:
dry-bulb temperature
Indoor
Unit size
(kW)
Outdoor
temperature
(
℃
DB)
Indoor temperature (
℃
WB/DB)
14/20 16/23
18/26
19/27 20/28 22/30 24/32
TC SC
TC
SC
TC
SC
TC
SC
TC
SC
TC SC TC
SC
kW kW
kW
kW
kW
kW
kW
kW
kW
kW
kW kW kW
kW
2.8
10.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.3 2.1 3.7
2.1
12.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.3 2.1 3.6
2.1
14.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.3 2.1 3.6
2.1
16.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.3 2.1 3.6
2.0
18.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.3 2.1 3.5
2.0
20.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.3 2.1 3.4
1.9
21.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.3 2.1 3.4
1.9
23.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.2 2.1 3.4
1.9
25.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.2 2.0 3.3
1.9
27.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.2 2.0 3.3
1.9
29.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.1 2.0 3.2
1.9
31.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.1 2.0 3.2
1.9
33.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.2 3.1 2.0 3.1
2.0
35.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.1 2.9 1.9 3.1
2.0
37.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.9
2.1 2.9 1.9 2.9
1.9
39.0 1.9
1.8
2.3
1.9
2.7
2.0
2.8 2.0
2.8
2.0 2.9 1.9 2.9
1.9
3.6
10.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.2 2.8 4.8
2.8
12.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.2 2.8 4.6
2.7
14.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.2 2.8 4.6
2.7
16.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.2 2.8 4.5
2.7
18.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.2 2.8 4.5
2.7
20.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.2 2.8 4.4
2.7
21.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.2 2.8 4.4
2.7
23.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.2 2.8 4.4
2.7
25.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.1 2.7 4.2
2.6
27.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.1 2.7 4.2
2.6
29.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.0 2.6 4.1
2.5
31.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.0 2.6 4.1
2.4
33.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.9
2.7 4.0 2.6 4.0
2.4
35.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.7
2.6 3.9 2.6 4.0
2.4
37.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.7
2.6 3.9 2.6 3.9
2.3
39.0 2.4
2.2
3.0
2.5
3.3
2.7
3.6 2.7
3.7
2.6 3.9 2.7 3.9
2.4
4.5
10.0 3.1
2.6
3.6
2.9
4.2
3.1
4.5 3.2
4.8
3.3 5.4 3.2 5.9
3.4
12.0 3.1
2.6
3.6
2.9
4.2
3.1
4.5 3.2
4.8
3.3 5.4 3.2 5.9
3.4
14.0 3.1
2.6
3.6
2.9
4.2
3.1
4.5 3.2
4.8
3.3 5.4 3.2 5.8
3.3
16.0 3.1
2.6
3.6
2.9
4.2
3.1
4.5 3.2
4.8
3.3 5.4 3.2 5.6
3.2
18.0 3.1
2.6
3.6
2.9
4.2
3.1
4.5 3.2
4.8
3.3 5.4 3.2 5.6
3.2
20.0 3.1
2.6
3.6
2.9
4.2
3.1
4.5 3.2
4.8
3.3 5.4 3.2 5.5
3.2
21.0 3.1
2.6
3.6
2.9
4.2
3.1
4.5 3.2
4.8
3.3 5.4 3.2 5.4
3.1
Summary of Contents for MDVi-D100Q4/N1-C
Page 11: ...Dimensions MHVAC DTSM 2010 03 Compact Four Way Cassette Type 10 3 Dimensions...
Page 12: ...MHVAC DTSM 2010 03 Service Space Compact Four Way Cassette Type 11 4 Service Space...
Page 15: ...Wiring Diagram MHVAC DTSM 2010 03 Compact Four Way Cassette Type 14 MDVi D45Q4 BN1...
Page 16: ...MHVAC DTSM 2010 03 Wiring Diagram Compact Four Way Cassette Type 15 MDVi D56Q4 BN1...
Page 63: ...Wiring Diagrams MHVAC DTSM 2010 03 Low Static Pressure Duct Type 62 6 Wiring Diagrams...
Page 106: ...MHVAC DTSM 2010 03 Service Space New Middle Static Pressure Duct Type A5 105 4 Service Space...
Page 108: ...MHVAC DTSM 2010 03 Wiring Diagrams New Middle Static Pressure Duct Type A5 107...
Page 110: ...MHVAC DTSM 2010 03 Air Velocity New Middle Static Pressure Duct Type A5 109...
Page 126: ...MHVAC DTSM 2010 03 Accessories New Middle Static Pressure Duct Type A5 125 11 Accessories...
Page 133: ...Service Space MHVAC DTSM 2010 03 Ceiling Floor Type 132 4 Service Space 600mm 600mm...
Page 204: ...MHVAC DTSM 2010 03 Wiring Diagram Exposed Concealed Floor standing Type 213 7 Wiring Diagram...
Page 241: ...Dimension MHVAC DTSM 2010 03 High Static Pressure Duct Type 250 3 Dimension...
Page 244: ...MHVAC DTSM 2010 03 Wiring Diagram High Static Pressure Duct Type 253 6 Wiring Diagram...
Page 258: ...MHVAC DTSM 2010 03 Service Space Console Type 267 4 Service Space...
Page 287: ...Indoor Unit Central Control Monitor System MHVAC DTSM 2010 03 Control System 296 Dimension...