MDS 05-3624A01, Rev. B
OEM Series™ I/O Guide
23
If an alarm does exist, a two-digit code (00–31) is displayed and the
alarm is identified as
MAJOR
or
MINOR
. A brief description of the alarm
code is also given. Detailed descriptions of event codes are provided in
.
If more than one alarm exists, the word
MORE
appears at the bottom of
the screen and additional alarms are viewed by pressing the
key. Alarms are displayed in ascending order, major alarms before
minor ones.
TOT [1–255 | ON | OFF]
This command sets or displays the transmitter time-out timer value
(1–255 seconds), as well as the timer status (
ON
or
OFF
). The command
parameter can be either the timer value or the status, but not both. The
parameter
ON
enables the timer;
OFF
disables the timer.
If the timer is on, and the radio remains keyed for a longer duration than
the
TOT
value, the transmitter is automatically unkeyed. When this
happens, the radio must be commanded back to an unkeyed state before
a new keying command is accepted.
By default the timer is
ON
and set to 30 seconds.
TX [xxx.xxx]
This command sets or displays the radio’s transmit frequency in MHz.
The frequency must be an integer multiple of the step size and must be
in the valid range. If the entered frequency is invalid, the terminal
interface displays the message
INCORRECT ENTRY
.
NOTE:
The frequency must be in the valid range for the sub-band
purchased, and may not be programmed “between” channels.
ENTER