26
MDS 1710A/C and MDS 2710A/C/D
MDS 05-3447A01, Rev. F
DUMP
This command displays all the programmed settings of the radio. The
HHT display is too small to list all the command settings at one time.
Therefore, this command is most useful if the command is issued from
a computer or full-screen terminal.
HREV
This command displays the transceiver’s hardware revision level if it
has been programmed at the factory.
INIT
The
INIT
command is used to re-initialize the radio’s operating parame-
ters to the factory defaults. This may be helpful when trying to resolve
configuration problems that may have resulted from the entry of one or
more improper command settings. Entry of this command allows you to
get back to a known working state. The following changes to the radio
are made when
INIT
is entered:
•
CTS
is set to 0
•
DATAKEY
is set to
ON
•
DEVICE
is set to
DCE
•
PTT
is set to 0
•
SCD
is set to 0
•
TOT
is set to 30 seconds and set to
ON
•
PWR
is set to +37 dBm (5 watts)
All other commands stay at their previously established settings.
INIT [2710]
This command sets the transceiver for operation outside the MDS model
P-20 chassis by setting the following parameters as shown.
ASENSE
ACTIVE HI
AMASK
FFFF FFFF
(assert alarm output on all alarms)
RXTOT
NONE
(receive time-out timer disabled)
This command can be used subsequent to using the
INIT 2720
command
to restore the standard transceiver defaults.
INIT [2720]
This command sets the transceiver for operation inside the model P-20
chassis by setting the following parameters as shown.
ASENSE
ACTIVE LO
AMASK
FFFF 0000
(trigger on major alarms)
RXTOT
20
(20 minute time-out timer)