10
MDS 1710A/C and MDS 2710A/C/D
MDS 05-3447A01, Rev. F
NOTE:
Use the radio in negative ground systems only.
5. Set the radio configuration. The transceiver is designed for quick
installation with a minimum of software configuration required in
most cases. The selections that must be made or verified for new
installations are:
• Transmit frequency
• Receive frequency
The operating frequencies are not set at the factory unless they were
specified at the time of order. Determine the transmit and receive
frequencies to be used, and follow the steps below to program them.
6. Connect a hand-held terminal (HHT) to the
DIAG.
connector. When
the HHT beeps, press
to receive the ready “>” prompt.
• Set the operating frequencies using the
TX xxx.xxxxx
(transmit) and
RX xxx.xxxxx
(receive) commands.
• Press
after each command. After programming, the HHT
reads
PROGRAMMED OK
to indicate successful entry.
• Set other transceiver parameters as required. A complete list of
transceiver commands is provided in
Section 5.0, TRANSCEIVER
PROGRAMMING
.
ENTER
ENTER