Atmosphere APS & Max APS Series 

User Guide120815, Rev: A/a 

7 / 11

 

SETTING UP 

WARNING: 

 

When not in use ALWAYS switch off the power switch located on the back panel, or 
unplug the generator. 

 

Never install above people. 

 

These  Fog  Generators  must  be  installed  in  an  upright  position  on  a  stable  and  level 
surface. 

 

Do not operate at less than 2 meters (6.5 ft.) from people. 

 

Use in a well ventilated area. 

 

Maximum  Operating  Pressure: 

ATMOSPHERE 

APS

  138  kPa  /  1.38  bar  /  20  psi, 

ATMOSPHERE

 APS

 H.O. / TOURING

 207 kPa / 2.07 bar / 30 psi, 

MAX 3000

 APS

 & 

MAX 

5000

  APS

 276 kPa / 2.76 bar / 40 psi, and 

MAX 5000

  APS

 H.O. / TOURING

 414 kPa / 

4.14 bar / 60 psi, 

 

GAS

 

REQUIREMENTS 

 

 

WARNING 

In  the  European  Community  the  gas  cylinder  and  regulator  must  be 
compliant with the Pressure Vessel Directive.   
In  North  America  the  gas  cylinder  must  be  manufactured,  inspected  and 
tested  in  accordance  with  U.S.  Department  of  Transportation  (DOT)  3AL 
and Transport Canada (TC) 3ALM requirements.

 

 

 

WARNING 

The CO

gas regulator and the N2 regulator do not use the same thread to 

mate with the cylinder.  Make sure to use a CO

2

 gas regulator with the CO

2

 

gas cylinder and to use a N

2

 gas regulator with the N

2

 cylinder.

 

 
  

 

 

WARNING 

Only  use  industrial  grade  Carbon  Dioxide  gas  (CO

2

)  or 

industrial grade Nitrogen gas (N

2

).

   

  

 

CAUTION 

To prevent gas leak and drop of pressure, ALWAYS use a neoprene washer 
when connecting the regulator to the cylinder

 

 

Summary of Contents for ATMOSPHERE APS Series

Page 1: ... A D A F A B R IQUÉ AU CA N A D A 10301 avenue Pelletier Montréal Québec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com ATMOSPHERE APS TM Series Haze Generator MAX APSTM Series Fog Generator USER GUIDE No 120815 Revision A a ...

Page 2: ...Atmosphere APS Max APS Series User Guide120815 Rev A a 2 11 Intentionally left blank ...

Page 3: ...etely before filling your generator with fog fluid and turning it on CAUTION This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensu...

Page 4: ...y stable temperature which integrates three types of fail safe systems Those three types of electronic fail safe systems are designed to protect against over and under heating conditions and against component failure The temperature is maintained within a narrow margin the HEAT yellow LED turn on off from time to time to indicate the control of temperature otherwise an error condition will result ...

Page 5: ...s a propellant when generating Fog Haze They are also used for purging the heating module s when the APS TM cycle is initiated Output pressure can be adjusted by mean of the CO2 or N2 gas regulator The ideal range for MAX TM Series is 10 to 40 psi and the H O TOURING TM Version is 10 to 60 psi for the ATMOSPHERETM Series it is 5 to 20 psi and the H O TOURINGTM Version is 5 to 30 psi FILLING OF THE...

Page 6: ...all HEAT indicating the start of the heating cycle which will last approximately 10 minutes When the temperature reaches a pre adjusted level called the READY level indicated by a green LED the HEAT yellow LED will turn off The Automatic Purging System TM APS TM will be automatically initiated After the first purging cycle is completed approx time 30 to 60 sec the generator is ready to produce fog...

Page 7: ...URING 414 kPa 4 14 bar 60 psi GAS REQUIREMENTS WARNING In the European Community the gas cylinder and regulator must be compliant with the Pressure Vessel Directive In North America the gas cylinder must be manufactured inspected and tested in accordance with U S Department of Transportation DOT 3AL and Transport Canada TC 3ALM requirements WARNING The CO2 gas regulator and the N2 regulator do not...

Page 8: ...itre US oz per hour 138 kPa 1 38 bar 20 psi 0 055 1 85 0 055 1 85 207 kPa 2 07 bar 30 psi 0 11 3 7 0 11 3 7 276 kPa 2 76 bar 40 psi 1 34 1 34 2 6 88 2 6 88 414 kPa 4 14 bar 60 psi 4 5 120 GAS Type industrial grade quality CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 N2 Only Consumption in Kg Lb per hour 138 kPa 1 38 bar 20 psi 0 18 4 0 18 4 207 kPa 2 07 bar 30 ps...

Page 9: ...ranty MDG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines responsibility for any losses costs or damages resulting from its use MDG Fog Generators Ltd shall not be liable for consequential damage in case of any failure to meet the conditions of any warranty or shipping ...

Page 10: ...Atmosphere APS Max APS Series User Guide120815 Rev A a 10 11 DECLARATION OF CONFORMITY ...

Page 11: ...Atmosphere APS Max APS Series User Guide120815 Rev A a 11 11 NOTE ...

Reviews: