Atmosphere APS & Max APS Series 

User Guide120815, Rev: A/a 

6 / 11

 

OPERATING INSTRUCTIONS 

 

The  MDG  Fog  Generators  are  quite  easy  to  operate  and  require  no  preventive 
maintenance.  They are supplied with a removable remote control.  A DMX Interface can 
be bought as an option. 
 
When the MAIN POWER (115 or 230Vac) and the MAIN POWER SWITCH is applied, the 
generator is  placed in stand-by mode.  When in stand-by mode, most of the electronic 
controls are off (except for the three types of fail-safe systems), waiting for the ON switch 
on the remote control to be activated. 
 
When the ON switch is pressed, the red LED indicating that the unit is working will light 
up, as well as the yellow LED call HEAT, indicating the start of the heating cycle which will 
last approximately 10 minutes.  When the temperature reaches a pre-adjusted level called 
the  READY  level  (indicated  by  a  green  LED),  the  HEAT  yellow  LED  will  turn  off.    The 
Automatic Purging System

TM

 (APS

TM

) will be automatically initiated. 

 
After  the  first  purging  cycle  is  completed  (approx.  time  30  to  60  sec.)  the  generator  is 
ready  to  produce  fog.    The  amount  of  the  fog  /  haze  emission  can  be  controlled  by 
adjusting the working pressure of the CO

2

 gas regulator.  

 
When an overheating condition is detected, or if the internal temperature reaches 60°C 
(140°F),  a  safety  circuit  is  triggered.    This  circuit  removes  the  power  to  the  heating 
elements, preventing hazardous conditions. 
 
When an under-heating condition occurs, the generator will stop producing fog until the 
temperature of the heating module is back within parameters. 

 

 

 

Summary of Contents for ATMOSPHERE APS Series

Page 1: ... A D A F A B R IQUÉ AU CA N A D A 10301 avenue Pelletier Montréal Québec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com ATMOSPHERE APS TM Series Haze Generator MAX APSTM Series Fog Generator USER GUIDE No 120815 Revision A a ...

Page 2: ...Atmosphere APS Max APS Series User Guide120815 Rev A a 2 11 Intentionally left blank ...

Page 3: ...etely before filling your generator with fog fluid and turning it on CAUTION This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensu...

Page 4: ...y stable temperature which integrates three types of fail safe systems Those three types of electronic fail safe systems are designed to protect against over and under heating conditions and against component failure The temperature is maintained within a narrow margin the HEAT yellow LED turn on off from time to time to indicate the control of temperature otherwise an error condition will result ...

Page 5: ...s a propellant when generating Fog Haze They are also used for purging the heating module s when the APS TM cycle is initiated Output pressure can be adjusted by mean of the CO2 or N2 gas regulator The ideal range for MAX TM Series is 10 to 40 psi and the H O TOURING TM Version is 10 to 60 psi for the ATMOSPHERETM Series it is 5 to 20 psi and the H O TOURINGTM Version is 5 to 30 psi FILLING OF THE...

Page 6: ...all HEAT indicating the start of the heating cycle which will last approximately 10 minutes When the temperature reaches a pre adjusted level called the READY level indicated by a green LED the HEAT yellow LED will turn off The Automatic Purging System TM APS TM will be automatically initiated After the first purging cycle is completed approx time 30 to 60 sec the generator is ready to produce fog...

Page 7: ...URING 414 kPa 4 14 bar 60 psi GAS REQUIREMENTS WARNING In the European Community the gas cylinder and regulator must be compliant with the Pressure Vessel Directive In North America the gas cylinder must be manufactured inspected and tested in accordance with U S Department of Transportation DOT 3AL and Transport Canada TC 3ALM requirements WARNING The CO2 gas regulator and the N2 regulator do not...

Page 8: ...itre US oz per hour 138 kPa 1 38 bar 20 psi 0 055 1 85 0 055 1 85 207 kPa 2 07 bar 30 psi 0 11 3 7 0 11 3 7 276 kPa 2 76 bar 40 psi 1 34 1 34 2 6 88 2 6 88 414 kPa 4 14 bar 60 psi 4 5 120 GAS Type industrial grade quality CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 N2 Only Consumption in Kg Lb per hour 138 kPa 1 38 bar 20 psi 0 18 4 0 18 4 207 kPa 2 07 bar 30 ps...

Page 9: ...ranty MDG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines responsibility for any losses costs or damages resulting from its use MDG Fog Generators Ltd shall not be liable for consequential damage in case of any failure to meet the conditions of any warranty or shipping ...

Page 10: ...Atmosphere APS Max APS Series User Guide120815 Rev A a 10 11 DECLARATION OF CONFORMITY ...

Page 11: ...Atmosphere APS Max APS Series User Guide120815 Rev A a 11 11 NOTE ...

Reviews: