background image

 

 

Atmosphere APS & Max APS Series 

User Guide120815, Rev: A/a 

9 / 11

 

WARRANTY 

 

When  installed  and  operated  as  recommended,  MDG  Fog  Generators  Ltd., 

guarantees that this product will remain free of defects in parts and labor for a period 
of five (5) years from the moment it is delivered.  This warranty does not apply if the 
product has been modified without our written authorization, or repaired without a 
written authorization from MDG or one of is authorized service center, or if it is used 
under conditions for which it has not been designed, or if a none MDG Fog Fluid has 
been  used.    MDG  Fog  Generators  Ltd  is  not  responsible  for  any  damages  resulting 
from a faulty installation or from abusive use of the product. 

 
If any device is found unsatisfactory under the terms of this warranty, MDG Fog 

Generators Ltd will repair or replace it free of all charges except transportation costs. 

 
This  warranty  applies  only  to  the  product  itself  and  MDG  Fog  Generators  Ltd 

declines responsibility for any losses, costs, or damages resulting from its use. 

 
MDG Fog Generators Ltd shall not be liable for consequential damage in case of 

any  failure  to  meet  the  conditions  of  any  warranty  or  shipping  schedule,  nor  will 
claims for labor, loss of profits, repairs, or other expenses incidental to replacement be 
allowed. 

 
The  repair  or  replacement  of  the  product,  by  MDG  Fog  Generators  Ltd  shall 

constitute fulfillment of all obligations to the purchaser. 

 

No other guarantees or warranties, expressed or implied, are made by MDG Fog 

Generators Ltd in connection with its products.  This warranty is nontransferable and 
applies to the original purchaser only. 

 

To obtain satisfaction under the terms of this warranty, contact your local sales 

office, and we will be pleased to help you.

 

 

 

Summary of Contents for ATMOSPHERE APS Series

Page 1: ... A D A F A B R IQUÉ AU CA N A D A 10301 avenue Pelletier Montréal Québec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com ATMOSPHERE APS TM Series Haze Generator MAX APSTM Series Fog Generator USER GUIDE No 120815 Revision A a ...

Page 2: ...Atmosphere APS Max APS Series User Guide120815 Rev A a 2 11 Intentionally left blank ...

Page 3: ...etely before filling your generator with fog fluid and turning it on CAUTION This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensu...

Page 4: ...y stable temperature which integrates three types of fail safe systems Those three types of electronic fail safe systems are designed to protect against over and under heating conditions and against component failure The temperature is maintained within a narrow margin the HEAT yellow LED turn on off from time to time to indicate the control of temperature otherwise an error condition will result ...

Page 5: ...s a propellant when generating Fog Haze They are also used for purging the heating module s when the APS TM cycle is initiated Output pressure can be adjusted by mean of the CO2 or N2 gas regulator The ideal range for MAX TM Series is 10 to 40 psi and the H O TOURING TM Version is 10 to 60 psi for the ATMOSPHERETM Series it is 5 to 20 psi and the H O TOURINGTM Version is 5 to 30 psi FILLING OF THE...

Page 6: ...all HEAT indicating the start of the heating cycle which will last approximately 10 minutes When the temperature reaches a pre adjusted level called the READY level indicated by a green LED the HEAT yellow LED will turn off The Automatic Purging System TM APS TM will be automatically initiated After the first purging cycle is completed approx time 30 to 60 sec the generator is ready to produce fog...

Page 7: ...URING 414 kPa 4 14 bar 60 psi GAS REQUIREMENTS WARNING In the European Community the gas cylinder and regulator must be compliant with the Pressure Vessel Directive In North America the gas cylinder must be manufactured inspected and tested in accordance with U S Department of Transportation DOT 3AL and Transport Canada TC 3ALM requirements WARNING The CO2 gas regulator and the N2 regulator do not...

Page 8: ...itre US oz per hour 138 kPa 1 38 bar 20 psi 0 055 1 85 0 055 1 85 207 kPa 2 07 bar 30 psi 0 11 3 7 0 11 3 7 276 kPa 2 76 bar 40 psi 1 34 1 34 2 6 88 2 6 88 414 kPa 4 14 bar 60 psi 4 5 120 GAS Type industrial grade quality CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 CO2 or N2 N2 Only Consumption in Kg Lb per hour 138 kPa 1 38 bar 20 psi 0 18 4 0 18 4 207 kPa 2 07 bar 30 ps...

Page 9: ...ranty MDG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines responsibility for any losses costs or damages resulting from its use MDG Fog Generators Ltd shall not be liable for consequential damage in case of any failure to meet the conditions of any warranty or shipping ...

Page 10: ...Atmosphere APS Max APS Series User Guide120815 Rev A a 10 11 DECLARATION OF CONFORMITY ...

Page 11: ...Atmosphere APS Max APS Series User Guide120815 Rev A a 11 11 NOTE ...