Charging from Mains Power
Symptom
Possible Cause
Remedy
No power to charger
Mains power not connected
Connect mains power
Charger not plugged in
Plug in mains charger
Charger not turned on
Turn on charger
RCD tripped
Reset RCD Fig 1
No charge with charger on
Tripped circuit breaker
Reset circuit breaker CB3 Fig.1
Incorrect charger setting
Set charger to correct battery type and
power setting (AGM for standard batteries)
Battery voltage too low (less than 6
volts)
Change charger setting to “Supply” until
battery voltage reads minimum of 6 volts
then choose setting “recondition” if this
function is available. Choose “AGM” if not
available.
Charger Error Codes
LCD
Power On
LED
Fault
Remedy
Err
Slow Flashing
Short circuit or reverse connection
of terminals
Check connections aren’t touching, or
check terminals are correctly connected
F01
Fast flashing
Bulk charging has timed out and
stopped after 10 hours
Battery may be faulty
Charge rate may be too low
Load on battery may be too high
F02
Fast flashing
Soft Start has timed out as battery
has not reached 10v after 2 hours
Battery may be faulty, check the battery or
try and charge again
F03
Fast flashing
Absorption has been charging for
more than 20 hours and is now in
float mode
Battery may be faulty or there is a load on
the battery
CLd
Battery temp is less than 0°C.
Charging at reduced current to
protect the battery
Warm the battery up
HtC
Battery temp is greater than 45°C,
the charger voltage is reducing to
protect the battery
Cool the battery down
OTP
Fast flashing
The charger HAS OVERHEATED
(>70°C) and has switched off
Ensure adequate ventilation around
charger
HT
The charger has overheated
(>55°C) derating the output of
the charger
Ensure adequate ventilation around
charger
OLC
Fast Flashing
Sensor wires are not connected to
the positive/negative terminals
If DC leads have been cut for hard wiring,
check the sensor wires are included in both
positive and negative connections.
OCP
Fa
st flashing
The charger has encountered an
error
Contact Brown & Watson Interna�onal
Summary of Contents for Robson XTT 2015
Page 33: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 29 Pole Diagram...
Page 48: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 44 Wiring Diagram Switch Panel...
Page 76: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 72 Hub Assembly...
Page 77: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 73 Trailing Arm Bushes...
Page 108: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 104...