INSTALLATION OF TEMPERATURE PROBE
The temperature probe must be connected to the control unit and to
the duct (
1
) of a kit (see diagram below) and has a length of 2.5 m.
Greater distances require the use of and extension to be provided by
the installer.
PROBE INSTALLATION
Insert the plastic piece
C
in
D
and screw in
B
without forcing it.
On the threaded part of piece
D
insert washer
E
The group thus formed
A1
must be inserted on the rigid part of
the cable of probe
A
Identify the pass-through hole for insertion of the probe on the
duct (
1
); on the grille at lower right alongside the fan.
Insert in the hole the cable of probe
A
with the block
A1
and
secure it on the other side with the nut
F
Insert the other end of the cable of probe
A
in the control unit
in the indicated position (12-11)
A1
F
B
A1
A
B
C