2-INSTALLATION
Technical Dept. - All rights reserved - Reproduction prohibited
MAINTENANCE
The flue must be kept clean, since the deposit of soot or unburned oils reduces the cross-section reducing the draught and thus
compromising the efficient operation of the stove and, if large build-ups accumulate, can catch fire. The flue and chimney pot must be
cleaned and checked by a qualified chimney sweep at least once a year. Once the inspection/maintenance has been performed, request a
written report that the system is safe.
Failure to perform cleaning jeopardises the system’s safety.
CHIMNEY POT
The chimneypot is a crucial element for the heating appliance to work properly: we recommend a wind proof chimneypot (A), see Figure 7.
The area of the opening for smoke
extraction must be at least double
the cross-section of the flue/lined
system, and arranged so that smoke
outlet is ensured even in strong wind.
The chimney must prevent rain,
snow or animals from entering the
chimney. The height of outflow into
the atmosphere must be beyond the
reflux area due to the shape of the roof
or any obstacles near the outlet (see
Figures 2-3-4-5-6).
CHIMNEY COMPONENTS
FIGURE 8
FIGURE 7
LEGEND:
(1) CHIMNEYPOT
(2) REFLUX CHANNEL
(3) SMOKE DUCT
(4) THERMAL INSULATION
(5) OUTSIDE WALL
(6) CHIMNEY FITTING
(7) SMOKE DUCT
(8) HEAT GENERATOR
(9) INSPECTION ACCESS PANEL