42
31-SAFETY DEVICES
SAFETY DEVICES
The product is fitted with the following safety devices.
SMOKE TEMPERATURE PROBE
It detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the preset
value.
PELLET HOPPER TEMPERATURE PROBE
If the temperature exceeds the preset safety value, it immediately stops the product, which must cool down before the stove is restarted.
ELECTRICAL SAFETY
The product is protected against power surges by a general fuse located in the control panel on the back. Other fuses that protect the
circuit boards are located on the latter.
SMOKE FAN BREAKAGE
If the fan stops, the circuit board promptly blocks the supply of pellets and the alarm is displayed.
GEAR MOTOR BREAKAGE
If the gear motor stops, the product switches off and the relative alarm is signalled.
TEMPORARY POWER CUT
If a power cut occurs during operation, the product automatically sets itself in cooling mode when the power is restored and then it
restarts.
FAILED START-UP
If no flame lights during start-up, the product will go into alarm conditions.
IT IS FORBIDDEN TO TAMPER WITH THE SAFETY DEVICES
It is possible to relight the product and therefore restore the automatic operation of the probe only after having eliminated the cause of
the intervention of the safety system. This manual will help you understand which anomaly has occurred, and explain how to intervene
according to the alarm message displayed on the appliance.
Summary of Contents for LINEA Comfort Air
Page 45: ......
Page 46: ......
Page 47: ......
Page 78: ...30 23 TIMER Temperature selection option T1 T2 T3...
Page 84: ...36 27 SUMMER WINTER Option to select the operating season...
Page 88: ...40 29 SOFTWAREVERSION SOFTWAREVERSIONS continuation screen...
Page 111: ......