28
6-DISASSEMBLING THE SIDE PANELS
REAR COVER FOR THE HYDRAULIC KIT
On the back of the stove there is a removable cover “
R
” for a possible inspection of the hydraulic kit. Remove the cover “
R
” by loosening the
two upper screws “
p
” and lifting the cover “
R
” so as to release the insert “
u
” of the cover from the insert “
t
” of the boiler.
ANTI-CONDENSATION VALVE KIT ASSEMBLY
The anti-condensation valve is used in solid fuel boilers to prevent the return of cold water into the boiler or stove, resulting in the
formation of condensation.
The prolonged formation of condensation causes permanent damage to the heat exchanger.
A higher return temperature reduces the formation of condensation of the fumes and extends the life of the boiler.
Valves available on the market offer various calibrations. MCZ recommends using the model provided. The thermostatic sensor immersed
directly in the fluid “feels” the temperature and diverts the route according to the required value (55°C).
The valve is supplied with the stove and
must be installed
according to the instructions in the dedicated manual.
JAZZ HYDROMATIC 30 H1 ACS
JAZZ HYDROMATIC 30 H1