24-TROUBLESHOOTING
Technical Dept. - All rights reserved - Reproduction prohibited
ANOMALIES RELATED TO THE HYDRAULIC CIRCUIT
ANOMALY
POSSIBLE CAUSES
SOLUTIONS
No increase in temperature with stove in
operation
Incorrect combustion adjustment.
Check recipe
Boiler / system dirty.
Check and clean the boiler.
Insufficient stove power
Check that the stove is properly sized for the
requirements of the system
Poor pellet quality
Using pellets from the producer
Condensation in boiler
Incorrect boiler or pump temperature
setting
Set the stove or the pump to a higher
temperature
Insufficient fuel consumption.
Check recipe
Radiators cold in winter
Room thermostat (local or remote) set
too low. If remote thermostat, check if it
is defective.
Set to higher temperature or replace (if
remote).
Circulator does not run because it is
blocked.
Free up the circulator by removing
the plug and turning the shaft with a
screwdriver.
Circulator does not go round.
Check the electrical connections of the
circulator; replace if necessary.
Radiators have air in them
Vent the radiators
Hot water is not provided
Circulator (pump) blocked
Free the circulator (pump)
Noises and gurgling
Air in the system
Release the air and fill the system
If the stove is NOT used as described in this instruction manual, the manufacturer declines all responsibility for
damage to persons and property that may arise. The manufacturer furthermore refuses to accept responsibility for
damage to persons and property arising from the failure to observe all the rules contained in the manual and in
particular:
• The operations in italics must be carried out by specialised personnel from the manufacturer
• All the necessary measures and/or precautions must be adopted when performing maintenance, cleaning and
repairs.
• Do not tamper with the safety devices.
• Do not remove the safety devices.
• Connect the stove to an efficient smoke expulsion system.
• First, check that the environment where it is to be installed is properly ventilated.