33
25-USER MENU
Technical Dept. - All rights reserved - Reproduction prohibited
NTC 1
Room probe - terminal block position 3-4
•
to change the values
•
Available values -ON-OFF-T.EXT
•
to confirm and go back to the previous page (+beep)
•
to exit without confirming (+beep)
With INSTALLATION SET 5 and 6 configuration, NTC1 is at OFF because only the call to the
water temperature from the puffer counts.
It can be activated through menu - NTC1 - ON: in
this case only the Room T is displayed
See the AUX1 menu for other functions.
NTC 2
Puffer probe - terminal block position 1-2
•
Displayable values -ON-OFF-T.EXT as set in the INSTALLATION SET configuration
NTC 3
Storage tank probe - terminal block position 5-6
•
Displayable values -ON-OFF-T.EXT as set in the INSTALLATION SET configuration
Can be activated with system 5-6 to view T med puffer
•
to change the values
•
Available values -ON-OFF-T.EXT
•
to confirm and go back to the previous page (+beep)
•
to exit without confirming (+beep)